7. Maintenance
1. Unscrew the locking screw on the air intake grille on the underside of the device.
2. Pull the air intake grille downwards out of the device.
3. Remove any lint and adhering dirt from the air intake grille.
4. Put one hand on the top of the device to hold it and insert the air intake grille into the
device from the bottom.
5. Fasten the air intake grille and the device with the locking screw.
Cleaning the device
Do not clean the device with a high-pressure cleaner. Only use a damp cloth and mild cleaning
agents to clean the device. Acids, acetone or solvents can damage the housing or device com-
ponents.
8. Disposal
Old equipment contains valuable materials which are designed for re-processing. The
vacuum cleaners must not be thrown away in the normal household waste, but should
be disposed of at a suitable proper collection system, e. g. via your communal dispos-
al location.
9. Technical data
Type
Voltage
Frequency
Power consumption (max.)
Fuse
Motor output
Air volume
Air speed
Sound level
Protection class
Protection type
Relative drying time
Width
Depth
Height
Weight
V
Hz
W
A
W
l/s
m/s
dB(A)
IP
s
mm
mm
mm
kg
23
WHT
220-240
50/60
1000
16
1000
38
87
69
II
23
17
268
182
304
3.0
CLAGE
EN