Jung eNet FMJ50700UP Instrucciones De Servicio página 7

Actuador persianas 1 fase mini
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Actuador persianas eNet 1 fase mini
Repeater mode
Channel settings
Parameters
Operating hours up
Operating hours down
Extended channel settings
Parameters
Operating mode
Manual commissioning
Local Operation
Running time
82581443
J0082581443
On, Off
Basic setting: Off
Setting options, Basic set­
ting
0...65535
Basic setting: Current value
0...65535
Basic setting: Current value
Setting options, Basic set­
ting
Roller shutter
Venetian blind
Awning
Basic setting: Roller shutter
On, Off
Basic setting: On
On, Off
Basic setting: On
1 ... 600 sec
Basic setting: 120 s
7/11
In addition to its other func-
tions, the device can be used
as a repeater. In the "On" set-
ting, the device repeats all the
received telegrams.
Explanations
The time is counted during
which the load is physically
switched on (relay contact clo-
sed).
This parameter can be reset to
"0", for example after exchan-
ging the load.
The Reset button is used to
reset the meter to "0". The de-
vice must be programmed to
apply the change.
The time is counted during
which the load is physically
switched on (relay contact clo-
sed).
This parameter can be reset to
"0", for example after exchan-
ging the load.
The Reset button is used to
reset the meter to "0". The de-
vice must be programmed to
apply the change.
Explanations
See Device and channels.
Blocks manual commissioning
for the device channel. In the
"Off" setting, the device can-
not be reset to the factory set-
ting.
Blocks the output for operation
using the button.
Absolute time which the
blind/shutter requires from the
top to the bottom end position.
The entry is essential if scene
or position movements are to
occur.
24.03.2017

Publicidad

Tabla de contenido
loading

Tabla de contenido