Rutland 504 "e-Furl" Windcharger
Installation and Operation
Rutland 504 "E-Furl"
Windcharger
(12V)
Owners Manual
Installation and Operation
Doc. No: SM-151 Issue A 07/01/2011
Marlec Engineering Co Ltd

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Marlec Rutland 504 E-Furl

  • Página 1 Rutland 504 “e-Furl” Windcharger Installation and Operation Rutland 504 “E-Furl” Windcharger (12V) Owners Manual Installation and Operation Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 2 Rutland 504 “e-Furl” Windcharger Installation and Operation Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 3: Tabla De Contenido

    Maintenance and Troubleshooting Inspection and Maintenance...................16 Troubleshooting......................17 Installation Instructions (abbreviated) - French…………………………………..19 Installation Instructions (abbreviated) - Spanish………………………………….22 Installation Instructions (abbreviated) - German…………………………………25 For Your Records Purchase Information....................28 Limited Warranty.....................29 Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 4: Summary Of Features And Uses

    Provides a D.C. power supply to charge 12 V battery banks where low power is • needed for domestic devices as well as radio equipment etc. Designed for land & marine use. • Rutland 504 “E-Furl” Profile & Dimensions Safety outer ring Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 5: General Guidelines And Warnings

    Avoid leaving the turbine tied up for any period of time, we recommend that the turbine either be covered to give protection from the weather or removed and stored in a dry location. We recommend the use of Marlec charge regulator that includes a shutdown switch.
  • Página 6: Check You Have Received

    Rutland 503/504 Land Tower Kit & Rigging Kit ( CA-12/12 & CA-12/13 ) • Short section of stainless steel tube to adapt into your own mounting design • Voltmeter & Ammeter • Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 7: Assembly & Installation

    38.1 mm for the top 0.5 m minimum to (i) prevent accidental damage and (ii) meet warranty conditions. 3. Mount a charge regulator, from the Marlec range, to a suitable vertical surface and close to the battery. Follow instructions supplied with the charge regulator.
  • Página 8: Tower Preparation

    4. Check tightness of all screws. (Do not over- tighten). 5. Place the nose cone into position aligning the holes and press the snap rivets into the holes to secure. ( Fig. 2 B ) Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 9: Electrical Connections & Fitting To The Tower

    Take care to avoid all moving parts when raising and lowering the wind generator. When raised, secure the structure firmly in an upright position. Caution-The performance of your Windcharger will be impaired if the pole is not vertical. Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co Ltd...
  • Página 10: Typical Wiring Diagram For The Rutland 504 "E-Furl

    HRDi Regulator - This gives the option of charging two battery banks Fig 5 HRSi Regulator with Solar Module(max solar panel rating 80W. NB a diode must be fitted to the solar panel) Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 11: Siting The Windcharger

    Bear in mind that downwind obstructions can be as detrimental to performance as upwind obstructions (Fig.6). Fig 6 AREA OF TURBULENCE WIND DIRECTION Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 12: On Board Systems

    Wind charger on yachts, e.g. Rutland 504 Marine Mounting Kit CA-12/01 and Marine Stays Kit CA-12/32 available from Marlec Mizzen (Fig.9) Mizzen mounting is suitable on larger yachts, taking Fig.10...
  • Página 13: Land Based Systems

    Two forms of pivot tower are suggested in Figs 11 & 12. A portable Land Tower and Rigging Kit is Centre Pivoted Pole available from Marlec. Part Nos: CA-12/12 & CA-12/13 A suitable mounting pole can be erected using a Fig.12 Fig.9...
  • Página 14: Further System Requirements

    We strongly recommend that one of the charge • regulators available from Marlec is fitted to prevent batteries becoming overcharged in strong winds and during low energy consumption periods. A regulator is essential where gel and sealed batteries are used.
  • Página 15: Specification And Performance

    Met. Office. WINDSPEED CONVERSION: KNOTS = m/s x 1.944 MPH = m/s x 2.237 Wi nds pee d ( M / S) Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 16: Maintenance And Troubleshooting

    Note : The Wind charger is designed for continuous running, this achieves maximum resistance to water ingress, should the unit be restrained for any extended period it is recommended that it be covered or removed to a dry location. Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 17: Troubleshooting

    + and the battery +. If a reading is measured, providing there is sufficient wind, then the regulator is faulty. E If the wind turbine fails to deliver any current or open circuit V reading undertake the further tests below. Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 18 If the above checks have identified a need for spare parts or failed to identify the problem you should contact Marlec who can advise you of your nearest distributor in their world wide network. In the first instance we recommend that you contact the company from whom the product was originally purchased.
  • Página 19: Installation Instructions (Abbreviated) - French

    Rutland 504 “e-Furl” Windcharger Installation and Operation Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 20 Français Introduction Félicitations pour votre achat d’une éolienne Rutland 504 E-Furl ! Comme tous nos produits, elle a été fabriquée avec le plus grand soin, dans notre usine certifiée ISO 9001. Pour obtenir pleine satisfaction de votre éolienne Rutland 504, nous vous recommandons de lire entièrement ce manuel et de vous familiariser avec son contenu avant de commencer l’installation ou de l’utiliser.
  • Página 21 Le fusible fourni doit être installé pour protéger l'appareil. • L’éolienne Rutland 504 E-Furl est conçue pour une utilisation sur des bateaux à voiles ou cer- • taines applications terrestres. Lorsque des vents d’orage sont annoncés, l’éolienne peut être...
  • Página 22: Installation Instructions (Abbreviated) - Spanish

    50 derniers centimètres, pour prévenir tout risque de dégâts et effectuer un montage conforme aux exigences de la garantie. 3. Monter un régulateur, choisi dans la gamme proposée par Marlec, sur un plan vertical et à proximité des batteries. Suivre les instructions de montage fournies avec le régulateur.
  • Página 23 Rutland 504 “e-Furl” Windcharger Installation and Operation Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 24: Introducción

    Nota: Existen otros cargadores eólicos Rutland diseñados para instalaciones permanentes en • tierra, para obtener mayor información, comuníquese con Marlec o visite la página Web www.marlec.co.uk. Pautas y advertencias generales El diámetro externo del mástil de montaje NO DEBE exceder los 38.1mm aunque sea en los •...
  • Página 25: Installation Instructions (Abbreviated) - German

    Ajuste el fusible incluido para proteger el sistema. • El cargador Rutland 504 E-Furl es apropiado para barcos de vela y algunas aplicaciones • terrestres. Cuando se pronostica una tormenta de viento, se puede sujetar la turbina para minimizar el desgaste y daño particularmente cuando se encuentra instalada en...
  • Página 26 38.1mm para los primeros 0,6mm cómo mínimo para (i) evitar daños accidentales y (ii) cumplir con las condiciones de la garantía. 3. Monte un regulador de carga, del rango Marlec, sobre una superficie vertical adecuada y cerca de la batería. Siga las instrucciones proporcionadas con el regulador de carga.
  • Página 27 Rutland 504 “e-Furl” Windcharger Installation and Operation Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 28: Purchase Information

    Deutsche Einleitung Wir gratulieren und bedanken uns für den Erwerb Ihres Rutland 504 E-Furl Windchargers. Wir leisten die beste Sorgfalt bei der Herstellung von allen unseren Geräten gemäß dem anerkannten Betriebsstandard ISO9001. Zur Gewährleistung für alle Vorteile beim Gebrauch von Rutland 504 bitten wir Sie diese Anleitung vollständig durchzulesen, bevor Sie mit der Montage und...
  • Página 29 Die mitgelieferte Sicherung muss zum Schutz des Gerätes angebracht werden. • Der Rutland 504 E-Furl Windcharger eignet sich für Segelboote und für einige Anwendungen • zu Land. Wenn Sturmwinde vorhergesagt werden, kann die Turbine gedrosselt werden, um einen Verschleiß...
  • Página 30 Außendurchmesser von nicht größer als 38.1 mm und mindestens für den Oberen 0.6m, um (i)einen Nebenschaden zu vermeiden und (ii) die Bedingungen der Garantie zu erfüllen. 3. Montieren sie eines der Aufladekontrollgeräte von der Firma Marlec an eine geeignete senkrechte Oberfläche und in der Nähe der Batterie. Befolgen Sie die Anleitung, die mit dem Aufladekontrollgerät mitgeliefert wurde.
  • Página 31: For Your Records

    Rutland 504 “e-Furl” Windcharger Installation and Operation For Your Records For your future reference we recommend you note the following: Serial Number: Date of Purchase: Date of Installation: Type of Regulator: Doc. No: SM-151 Issue A 07/01/2011 Marlec Engineering Co...
  • Página 32: Limited Warranty

    Marlec's obligation in this respect is limited to replacing parts which have been promptly reported to the seller and are in the seller’s opinion defective and are so found by Marlec upon inspection. A valid proof of purchase will be required if making a warranty claim.