PERFORMANCE
Model
33011-3
33021-3
33031-3
32011-3/32011-1
32021-3/32021-1
32031-3/32031-1
30011-3
30021-3
30031-3
SAFETY INSTRUCTIONS
1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do
not disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in
water before disconnect the power.
5.
Release all pressure and drain all water from the system before servicing any component.
6.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7.
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life
threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use
of an extension cord to power this pump is not permitted.
8.
Wear safety goggles at all times when working with pumps.
9.
This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The
3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type
receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly
grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and
local codes and ordinances. All wiring should be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not
use damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING
TO USE ADAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
GPH of Water @ Total Feet Of Lift
HP
0 ft.
5 ft.
1/4
3450
3200
1/3
3600
3400
1/2
4100
3800
1/3
3800
3400
1/2
4300
3900
1/2
3900
3700
1/2
4600
4320
3/4
5150
4800
1
5500
5160
10 ft.
15 ft.
2800
2100
3000
2500
3500
2900
3000
2500
3500
3100
3400
3100
3840
3060
4320
3660
4680
4200
2
Max.
Lift
20 ft.
25 ft.
1500
200
26 ft.
1900
1000
28 ft.
2300
1600
29 ft.
1800
25 ft.
2500
1700
30 ft.
2700
2200
37 ft.
1800
22 ft.
2580
25 ft.
3480
2340
30 ft.