Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This control is a dual-function control having a tempera-
ture regulating control in series with a high-limit control.
The temperature control is a SPDT switch which opens on
a rise in temperature and will control one or two heating
elements.
THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the White-
Rodgers warranty.
WARNING
!
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.
AC ELECTRICAL RATINGS
UL and CSA recognized for resistive loads.
Temp Control
Voltage
30 amps
120-250 VAC
25 amps
277 VAC
12.5 amps
480 VAC
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
The limit control is a normally closed DPST switch which
opens on a rise in temperature to limit the maximum
allowable temperature. It has manual reset.
Both switches are calibrated to meet the requirements for
typical residential type storage tank water heaters.
Temperature Ratings:
Limit Control
40 amps
40 amps
25 amps
Printed in U.S.A.
756-50
Electric Water Heater Control
INSTALLATION INSTRUCTIONS
CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.
Following installation or replacement, follow
appliance manufacturers' recommended instal-
lation/service instructions to insure proper op-
eration.
Temperature control - Variable 90° to 150°F (32° to
Limit control - Fixed 170°F (77°C) with manual reset
DESCRIPTION
PRECAUTIONS
SPECIFICATIONS
66°C)
PART NO. 37-5785A
9714

Publicidad

loading

Resumen de contenidos para White Rodgers 756-50

  • Página 1 756-50 Electric Water Heater Control WHITE-RODGERS INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION This control is a dual-function control having a tempera- The limit control is a normally closed DPST switch which ture regulating control in series with a high-limit control.
  • Página 2 INSTALLATION Wiring All wiring must conform to local and national electrical codes and ordinances. Connect in accordance with wiring diagrams provided by the equipment manufacturer. If none are provided, the following represents a typical installation. Wiring Diagram for Typical Two-Element Residential Electric Storage Water Heater, Non-Simultaneous Operation.
  • Página 3 756-50 WHITE-RODGERS INSTRUCTIONS D’INSTALLATION Commande pour chauffe-eau électrique Opérateur : Il faut conserver ces instructions pour utilisation ultérieure ! IL FAUT LIRE ET SUIVRE SOIGNEUSEMENT TOUTES CES INSTRUCTIONS AVANT D’INSTALLER OU D’UTILISER CETTE COMMANDE POUR ÉVITER DES BLESSURES ET/OU D’ENDOMMAGER L’ÉQUIPEMENT.
  • Página 4 INSTALLATION Branchements Tous les branchements doivent être conformes aux codes et règlements électriques locaux et nationaux. Brancher selon les schémas fournis par le fabricant de l’équipement. Si aucun n’est fourni, les schémas suivants représentent une installation typique. Schéma de branchement pour chauffe-eau à ballon résidentiel typique à...
  • Página 5: Especificaciones

    756-50 WHITE-RODGERS Control del Calentador de Agua Eléctrico INSTRUCCIONES DE INSTALACION Operador: ¡ Guarde estas instrucciones para usarlas en el futuro! SI NO SE LEEN Y SE SIGUEN TODAS LAS INSTRUCCIONES CUIDADO- SAMENTE ANTES DE INSTALAR U OPERAR ESTE CONTROL SE PUEDEN PRODUCIR LESIONES PERSONALES Y/O DAÑO A LA PROPIEDAD.
  • Página 6: Instalacion

    INSTALACION Cableado Todo el cableado tiene que cumplir con las regulaciones y los códigos eléctricos nacionales y locales. Conéctelo según los diagramas de cableado ofrecidos por el fabricante del equipo. Si no viene ninguno incluido, a continuación se presenta una instalación típica. Diagrama de Cableado para Calentadores de Agua, de Dos Elementos, Típicos, de Almacenamiento, Eléctricos, Residenciales,...