Recommended duty limits for LU, AD and
ID/IDTA/IDK/IDKN/IDKT flat fan nozzles as a
function of wind speed:
Rule of thumb:
The higher the wind speed, the larger the nozzle size
in combination with minimal pressure is
recommended. The day curve of wind speeds should
be considered when spray application is planned.
Typically, the lowest wind can be expected in the
evening, overnight and early in the morning.
Delta T
Delta T is becoming one of the most important
standard indicators for acceptable spray conditions
referring to evaporation rate and droplet lifetime. It is
the agricultural term for wet bulb depression and
combines temperature and relative humidity. When
delta T is high, the evaporative potential is high and
droplet survival is lowered for smaller droplets. When
applying pesticides, Delta T should ideally be between
2 and 8 and not greater than 10 for coarse droplet
spray applications such as with ID/IDTA and
IDK/IDKN/IDKT nozzles.
Key Function Matrix
Keys
Mode
Mode/ On/
SET/ EL
Off
Change
mode
Wind Speed
(Hold to turn
---------------
power ON/
OFF)
Change
mode
Max. Wind
(Hold to turn
---------------
Speed
power ON/
OFF)
Change
mode
Avg. Wind
(Hold to turn
---------------
Speed
power ON/
OFF)
Change
mode
Hold to enter
Compass
(Hold to turn
Compass
power ON/
Calibration
OFF)
Hold to enter
Exit to
Crosswind
Compass
compass
Calibration
Hold to enter
Exit to
Headwind
Compass
compass
Calibration
Compass
---------------
Exit to compass
Calibration
Change
mode
Temperature
(Hold to turn
---------------
power ON/
OFF)
Change
mode
Wind Chill
(Hold to turn
---------------
power ON/
OFF)
Change
mode
Humidity
(Hold to turn
---------------
power ON/
OFF)
Change
mode
Wet Bulb
(Hold to turn
---------------
power ON/
OFF)
Change
mode
Dew Point
(Hold to turn
---------------
power ON/
OFF)
Change
mode
Hold to enter
Comfort Index
(Hold to turn
Solar Factor
power ON/
Setting
OFF)
Solar Factor
Exit to Comfort
---------------
Setting
Index
Change
mode
Delta T
(Hold to turn
---------------
power ON/
OFF)
Specifications
Measurement
Units
Wind Speed
Change
Temperature, Wind Chill
Units
Digitale Compass
Change
Relative Humidity
Units
Wet Bulb, Dew Point
Change
Units
Hold to mark
direction
Headwind
Crosswind
---------------
Change
Units
Change
Units
---------------
Change
Units
Change
Units
Change
Units
Advance
adjust
Change
Units
Range
Accuracy
0,4 – 40 m/s
± 3%
-20 – 60°C
± 1°C
0° - 360°
± 2°
0 – 100% RH
± 3% RH
-45° - 125°C
± 2°C
& 0 – 100% RH