Procedures for Bearing Components Connected to a Grease Plate
3.1.4.2.
machine has a grease plate on the machine housing or the shell. You add grease to components of
the bearing housing at this location. The correct procedure is to add grease when the cylinder
turns at wash speed, but obey these precautions:
• For all other grease maintenance, add grease with power removed from the machine.
• If the grease plate on your machine is not serviceable (if you must add grease at a different
location), add grease with power removed from the machine.
• If you must remove a guard to get access to the grease plate, prevent access to the machine by
other personnel.
If you obey these precautions, use the Manual mode to operate the machine at wash speed. Then
add grease at the grease plate.
Procedures for Motors
3.1.4.3.
grease maintenance is necessary. If a motor on your machine has grease fittings, it is necessary to
add grease. But the interval is usually longer than for other maintenance.
grease intervals and quantities for motors with specified frame sizes and speeds. You get this data
from the motor nameplate. Use
machine.
—If a motor on your machine does not have grease fittings, no
Table 7 in Section 3.1.2
27
Chapter 3. Routine Maintenance
Table 11
to record the data for the motors on your
PELLERIN MILNOR CORPORATION
—Your
gives motor