6. Solving problems

Failure
description
No power
No power, LED
flashing RED
No power, LED
flashing RED
Power output
switches off
repeatedly when
driving with a
mover
Battery doesn't
charge due to
freezing
temperature
7. Maintenance
The Peak Power Pack is maintenance-free, but must be fully
charged at least once per year, and after each use.
Important:
The PPP must be charged and switched off prior to a long
storage period.
Possible
Cause
Battery
discharged
Output
shorted
Over
temperature
Overload
Remedy
Charge
Check wiring
Cool down
Use correct tire pressure
and roller engagement
force. Avoid digging of the
nose wheel. Avoid
kerbstones. Use a PPP
properly sized for the
caravan/mover.
Move to an are with
temperature above 0 °C