The battery separators (MBR) are micro-
processor controlled, powerful, mechanical
contactors. A MBR can be used in a
system consisting of two batteries (a start
and an auxiliary battery), like for instance
in boats or in camping-cars.
Possibilities
Connection
according
battery voltage
(See Connection p. 2)
In some 12/24 V installations (like in a
vehicle), it is preferable that the auxiliary
battery or the appliances are powered
only
if
the
start
sufficient. By connecting a MBR between
the start battery and the auxiliary battery
or the appliances, the latter will only be
powered once the start battery voltage
has
reached
13.2/26.4
seconds.
4O9N4
BATTERY SEPARATOR
MBR 12/24-500
to
the
start
battery
voltage
is
V
during
60
Connection
of
auxiliary battery
(See Connection p. 2)
In a boat or in a camping-car it is usual to
connect a battery charger to the auxiliary
battery. By using a MBR, the start battery
will also be charged if the voltage of the
second battery is higher than 13.2/26.4 V
during
5
seconds.
boat/vehicle would stay without running
for a long time, your start battery will then
remain 100% charged. From the stop of
the charger, the contactor will open as
soon as it detects a voltage threshold
below 12.8/25.6 V during 60 seconds.
Contact for start assistance
(See Connection p. 2)
By connecting the terminal STATUS to the
positive (+) pole of the auxiliary battery
via the start contactor, the MBR will
commute the second battery at the start
of your boat/camping-car.
Security in case of overvoltage
(See Connection p. 2)
In case of a fault of the alternator voltage
regulator, the system voltage can easily
overcome the voltage limits allowed for
the
auxiliary
appliances. This is why, in case of an
overvoltage, the MBR will detect the fault
and will disconnect the auxiliary battery
and/or the appliances in order to protect
them.