SYMPTOM
PROBABLE CAUSE
Charge OFF at high
System temporarily shuts down due to
ambient temperature
high heat sink temperature
When charger turns
Output current display selection set for
on, output current
wrong IPN network address
displays but the
Bat– connected to PV– outside charge
value seems
controller
incorrect
Voltage or current
Display or charge controller IPN network
value displayed
addressed has changed
seems to be stuck
Display not communicating with charge
and does not change
controller
SPECIFICATIONS
SPECIFICATIONS
Output Current Rating
Nominal Battery Voltage
PV Input Voltage
Power Consumption
Charge Algorithm
Acceptance Voltage
Float Voltage
Equalization Voltage
Voltage Setpoint Limit
Auxiliary Output
• Aux. Battery Charge
• Load Control
ℑ
• Dusk-to-Dawn Control
Temperature Compensation
Power Conversion Efficiency
Cabinet Dimensions
Volt/Amp Accuracy/Range
Communication
Environmental
As a part of our continuous improvement process
specifications are subject to change without prior notice
ITEMS TO EXAMINE OR CORRECT
Improve ventilation or reduce PV power. Sufficient ventilation to prevent over
temperature shut down will improve reliability. See Technical Bulletin #100206.
Configure display IPN network address DIP switch to read desired output current.
PV- & BAT- must be separate external to the unit for proper operation and cannot
connect to a common location. External connection prevents proper operation of
internal shunts and current measurement system.
Configure display IPN network address DIP switch to properly read output current
of a charger present on the IPN network
Intermittent display cable.
Typical 0.35W standby • 1.0W Charge ON
3-stage Bulk/Acceptance/Float • plus Equalize
ℵ
14.4VDC
ℵ
13.2VDC
ℵ
15.2VDC
(range 10.0 – 40.0VDC
15.5VDC
Single output configurable as either: 20A load controller –or– 2A auxiliary battery charger
2A typical, same charge voltage as primary battery
ℵ
20A maximum, ON ≥12.6VDC
Variable Post–Dusk and Pre–Dawn timers
Optional sensor adjusts charge voltage based on battery temperature
–5.00 mV/°C/cell correction factor (Range 0.00 to –8.00 mV/°C/cell
6⅞"H x 6⅝"W x 3⅜"D (17.4cm x 16.8cm x 8.59cm)
Battery voltmeters 40.0VDC±0.50% FS • PV voltmeter 60.0VDC±0.50% FS
Blue Sky Energy's proprietary IPN Network interface
–40 to +40°C, 10 – 90% RH non-condensing
Solar Boost 3024iL & 3024DiL
ℜ
30A / 40A
12 / 24VDC
57VDC maximum
ℵ
(range 14.0 – 14.8VDC
, 10.0 – 40.0VDC
ℵ
(range 13.2 – 13.8VDC
, 10.0 – 40.0VDC
ℑ
) • automatic or manual
ℵ
(range 10.0 – 40.0VDC
ℵ
/ OFF ≤11.5VDC
(Range 10.0 – 40.0VDC
ℑ
, Range 0.5 – 20.0 hours
97% typical @ 28V / 24A Output
Ammeters 41.0A±0.50% FS
ℵ
SB3024i alone, voltages double for 24V battery
ℑ
With IPN-ProRemote
ℜ
40A with 12V battery and 12V PV modules
Installation and Operation Manual
ℑ
)
ℑ
)
ℑ
)
ℑ
ℑ
, or net battery AH
ℑ
) • sensor range –60 to +80°C
)
14