Gewa CP14 Manual Do Usuário página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
5 C
ONNECTIONS
Figure 4
Option: 3Way triggering
3Way triggering moves the Bell signal to its own
connection, resulting in a 2-cable setup. With this
method it is possible to use individual velocity
curves for Edge and Bell signals. Signals for Bow and
Edge remain in connection (1), whereas the bell is
connected to the Console via the outer jack of the
cymbal (2). See the table on the right-hand side for
all combinations of trigger inputs available for 3Way
triggering.
With this setup, load the matching "3W" Trigger
Bank version at the input channel to which the Bow
Component of your Cymbal is connected.
Other Manufacturers (Modules)
Although GEWA cymbals are manufactured to meet industry standards of analogue trigger sys-
Note
tems, GEWA does not guarantee flawless functioning with equipment of other manufacturers. The
operation of this product with 3rd party equipment is at your own risk. If you still decide to operate
this product with 3rd party drum modules, please take first note of the following hints:
 Check first whether your drum module supports the trigger types (Sensors) built into GEWA pads.
 Check whether the manufacturer of your module offers a trigger bank for the GEWA pad you
want to connect.
 Consult the owner´s manual of your drum module for Information about trigger setups, accessible
parameters and customization of 3
8
CP14 | CP14-AC | CP18 | CP18-AC - Owner´s Manual
& T
S
RIGGER
ETTINGS
(Trigger Type = 3Way)
party equipment.
rd
Standard
1
(Trigger Type = Dual)
The standard connection only utilizes one cable for all
component sensors (Bow, Bell and Edge). The required
Trigger Type (Dual) is set by default in the factory Trig-
ger Banks and Setups provided for GEWA Cymbals.
Connect the stereo cable to the cymbal, using
1
the jack closest to the middle hole (Z).
Connect the other plug of cable to one of the
2
following Trigger Inputs of your console:
Ride
|
Crash 1
|
Crash 2
In your Drum Console make sure that the cor-
rect Trigger Bank is loaded at the corresponding
Input channel. *
3
Default Trigger Banks:
CP14:
GEWA Crash 14inch
CP18:
GEWA Ride 18inch
*For more information about loading trigger
banks consult the owner´s manual of your GE-
WA Console.
Cymbal Component
Bow/Edge
1
Ride
Aux 1
Trigger
Inputs
Aux 2
Aux 3
CP14:
GEWA Crash 14inch 3W
Trigger
Banks:
CP18:
GEWA Ride 18inch 3W
|
Aux 1-4
|
(Hi-Hat)
Bell
2
+
Aux 1
+
Aux 2
+
Aux 3
+
Aux 4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp14-acCp18Cp18-ac

Tabla de contenido