Hach RTC Seie Manual Básico Del Usuario página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
Tag name
Parameter Unit
MEASUREMENT 1
Qeff 1
MEASUREMENT 2
Qsas 1
MEASUREMENT 3
Qsasm 1
MEASUREMENT 4
Vol 1
MEASUREMENT 5
Vols 1
MEASUREMENT 6
TSmL 1
MEASUREMENT 7
TSs s1
MEASUREMENT 8
SRT 1
ACTUAT VAR 9
SRTSP 1
ACTUAT VAR 10
Qs c1
ACTUAT VAR 11
Qs 1
ACTUAT VAR 12
Digi 1
ACTUAT VAR 13
msaSP 1
ACTUAT VAR 14
msasd 1
ACTUAT VAR 15
msash 1
ACTUAT VAR 16
msas 1
Tag name
Parameter Unit
MEASUREMENT 1
Qeff 1
MEASUREMENT 2
Qsas 1
MEASUREMENT 3
SRT 1
MEASUREMENT 4
Qeff 2
MEASUREMENT 5
Qsas 2
MEASUREMENT 6
SRT 2
ACTUAT VAR 7
SRTSP 1
ACTUAT VAR 8
Qs 1
ACTUAT VAR 9
Digi 1
ACTUAT VAR 10
msaSP 1
ACTUAT VAR 11
msas 1
ACTUAT VAR 12
SRTSP 2
Table 31 RTC111 SRT-module (1-channel)
Channel Description
L/s
1
L/s
1
kg/h
1
3
m
1
3
m
1
g/L
1
kg
1
days
1
days
1
L/s
1
L/s
1
no unit 1
kg/d
1
kg/d
1
kg/h
1
kg
1
Table 32 RTC111 SRT-module (2-channels)
Channel Description
L/s
1
L/s
1
days
1
L/s
2
L/s
2
days
2
days
1
L/s
1
no unit 1
kg/d
1
kg
1
days
2
Effluent flow as supplied to the RTC.
Surplus activated sludge flow
Sludge mass flow in surplus start sludge
Actually aerated volume
Averaged aerated volume during past sludge retention
time.
Averaged TS concentration in aeration basins during past
sludge retention time.
Mass of sludge in aeration basins, averaged for past
sludge retention time.
Calculated actual aerobic sludge retention time
Set point for aerobic sludge retention time
Theoretical flow set point for surplus start sludge flow
Effective set point for surplus activated sludge flow
including all preset limits.
Surplus activated sludge pump ON/OFF signal
Set point for sludge mass draw off.
Surplus activated sludge mass draw off during last
24 hours.
Actual surplus activated sludge mass draw off.
Surplus activated sludge mass draw off during actual
calendar day.
Effluent flow as supplied to the RTC.
Surplus activated sludge flow
Calculated actual aerobic sludge retention time
Effluent flow as supplied to the RTC.
Surplus activated sludge flow
Calculated actual aerobic sludge retention time
Set point for aerobic sludge retention time
Effective set point for surplus activated sludge flow
including all preset limits.
Surplus activated sludge pump ON/OFF signal
Set point for sludge mass draw off.
Surplus activated sludge mass draw off during actual
calendar day.
Set point for aerobic sludge retention time
English 25

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para Hach RTC Seie

Tabla de contenido