LED6 and buzzer alarm:
Flashes, indicating there is an overload.
-"OVERLOAD":
Causes:
The cell sensor is dirty.
The cell is not properly connected.
There is a metal object between the cell sheets.
The equipment is damaged.
Indication of absence of power in the cell: The green
LEDs column flashes.
Causes:
Absence of water flow.
Overload.
Disconnection of the electrolytic cell.
The chlorinator has stopped during the voltage
inverter process.
U S E R G U I D E
Corrective action:
Remove the cell and clean it, as explained in the guide.
Check that the cell cables are properly connected.
Turn off the equipment and remove the metal object
from the sheets.
Contact ESPA technical assistance service.
Corrective action:
Restore the water flow.
Check there is no overload.
Connect the electrolytic cell.
The equipment is cleaning the cell by polarity inversion.
This process takes about 5 minutes.
GB
13