•
Access advanced configuration by turning the two rotary switches to position 99.
•
Set the ID dip switch to the code of the first column in the system (column 0 typically).
•
Press the button corresponding to user 0 of the selected column. All the subsequent buttons will be
automatically associated to the users of the column itself in sequence.
•
Repeat the operation on all the columns.
•
Reset the ID dip switch in start position.
•
To quit advanced configuration, turn the two rotary switches to the door opening line and the guaranteed
conversation time setting positions.
Example:
System with 3 columns, the first with 4 users, the second with 6 users and the third with 8 users.
•
Access advanced configuration.
•
Set the ID dip switch to 0.
•
Press the first button connected to the door unit.
•
Set the ID dip switch to 1.
•
Press the fifth button connected to the door unit; this button will be associated to the user 0 of the column
1.
•
Set the ID dip switch to .
•
Press the eleventh button connected to the door unit; this button will be associated to the user 0 of the
column .
•
Reset the ID dip switch in start position.
•
Quit advanced configuration mode.
The final configuration will be:
4 USERS
EXPANSION MODULE 1038/17
Column 0
Column 1
start
start
§
The configuration of column 0 is not required if the default settings of the door unit are maintained
because all buttons are assigned to this column.
Repeat the operation on all the main door units.
If the door units are configured as secondary, but each one must call a different group of users, the following
DS1083-00B
6 USERS
Column 2
start
8 USERS
EXPANSION MODULE 1038/17
17