Spec:
By:
M22759/12-20 16 CONDUCTOR CABLE UNSHIELDED
Scope: This cable is designed specifically for use with Level-Trac Remote Level Indicator Sys-
tems for the span between the probe manifold and control unit. The probe side will be termi-
nated with high temperature, nickel plated steel, un-insulated ring terminals for connection to
the probes and common lug. Although designed specifically for Level-Trac equipment it is suit-
able for most high temperature, unshielded, instrument applications.
PRIMARY WIRE TYPE
CONDUCTOR SIZE
CONDUCTOR MATERIAL
CONDUCTOR DIAMETER
PRIMARY INSULATION MATERIAL
PRIMARY WIRE DIAMETER
NUMBER OF CONDUCTORS
COLOR CODE
JACKET MATERIAL
JACKET COLOR
JACKET THICKNESS
CABLE FINISHED DIAMETER
TEMPERATURE RATING
VOLTAGE RATING
Appendix C
M22759-12-20-16C
EXTRUDED WHITE PFA JACKET
M22759/12-20-9
20 19/32
NICKEL PLATED COPPER
.037" - .041"
PTFE
.056" - .060"
CABLE CONSTRUCTION
16
9-96-93-954-92-90-94-97-98-91
901,902,903,904,905,906
PFA
WHITE
.015" NOMINAL
.305" NOMINAL
PERFORMANCE CHARACTERISTICS
500º F / 260º C
600 VOLTS
14
Date:
July 16, 2009
Approved: