ENGLISH
MAIN MENU – DUMP PROGRAM:
It is possible to copy the user programs from a "master" unit [network cable connected to RS-485 output (15)]
to one or more "slave" units [network cable connected to RS-485 input (15)] At the same time you should set
the master and slave units so communication is possible (read the next point "RECEIVE DUMP" also before
you start!)
This is how you prepare the master unit:
Press the DIAL (4) until the first display on the right is shown.
Press the NEXT button (6) until the display shows "DUMP PROGRAM"
Press the ENTER button (11) to enter the submenu.
The display asks "Are you sure?" and proposes "NO"
Turn the DIAL (4) to change the "NO" to "YES" if you want to send a dump.
NOW WAIT and prepare the slaves first (see next point) before you continue!
Press the ENTER button (11) to confirm The master starts dumping all programs. If an error occurs The
display shows "ERR".
Remark: the dumping process can't be interrupted. When the dump is finished the master returns to normal
working mode.
MAIN MENU – RECEIVE DUMP:
It is possible to copy the user programs from a "master" unit [network cable connected to RS-485 output (15)]
to one or more "slave" units [network cable connected to RS-485 input (15)] At the same time you should set
the master and slave units so communication is possible (read the previous point "DUMP PROGRAM" also
before you start!)
This is how you prepare the slave unit:
Press the DIAL (4) until the first display on the right is shown.
Press the NEXT button (6) until the display shows "RECEIVE DUMP"
Press the ENTER button (11) to start the receiving process, the display shows
"RECEIVING DUMP" while the unit is waiting for the master.
NOW you can start the DUMP program on the master!
Remark: press the RECALL button (7) if you want to interrupt the process.
When the dump is finished the slave returns to normal working mode.
PC SOFTWARE
Our personal favorite because it's so much faster! The PC-software is so easy to use that it doesn't need a
lot of explanation. If you are familiar with the use of all parameters than you can use it right away, we will just
give you some basic explanations. You can connect the DLP-6 MK2 in two different ways to your PC:
Via USB: This is the easiest way but the length of your cable is limited to only
5m. Use a standard USB-cable to connect the USB-slot on the rear of the
DLP-6 MK2 to one of the USB-slots of your PC.
Via RS485: This is a little more complicated but the length of your cable can
be extended to 100m. You will need the supplied RS485/USB converter (see
picture). Connect one side of a standard straight CAT-5E network cable to one
of the RS-485 connectors on the rear of the DLP-6 MK2. Connect the other
side of the network cable to the RJ-45 input of the RS485/USB converter and
insert it in a free USB-slot on your PC.
INSTALLING THE SOFTWARE:
Very important: before you install the Windows
USB or RS485 communication!
Part1 – installing the USB driver
AUTOMATIC installation:
First connect the DLP-6 MK2 with your PC (via USB or RS485) and switch the DLP-6 MK2 on.
Windows will detect new hardware and ask you if it can search and install a driver via internet: accept
this option. Windows will try to install the driver automatically. After some time windows will inform you
if it could install the driver or not.
Proceed with the manual driver installation if the driver could not be found and installed.
SYNQ
®
®
software you should install a driver to ensure the
10/96
OPERATION MANUAL
DLP-6 MK2