Connection
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid
specification should be compared with that of the device
(see rating plate). Connect the device only in case of
compliance!
•
Before connecting the power supply to the device, the local power grid specification
should be compared with the value of voltage and frequency on the type plate.
Permissible voltage tolerance is ± 10%.
•
A multipolar switch must be switched on between the device and the electrical
installation, appropriate for the device's power. The switch with at least 3 mm
opening must be easily accessible.
•
Connection to the power supply installation must comply with the applicable
international, national and local regulations.
•
The device is supplied with the connection cable (2.3 m long), without plug.