Recommended Sanitizing Procedures
1. Turn off feed water.
2. Drain storage tank by opening RO faucet.
3. Remove all membranes and filters.
4. Put 3 tablespoons of chlorine in prefilter housing.
5. Secure all housings to avoid leaks. Turn on feed water.
6. When water flow is constant and no air spurts are present, turn off RO faucet.
7. Let system set for 30 minutes.
8. Open RO faucet, let water run for a minimum of 5 minutes or until chlorine is
no
longer present.
9. Turn off feed water. When water stops flowing, remove all housings, being
careful
of overflow.
10. Replace all membranes and filters. Follow normal start-up procedures.
Testing
Unit performance should be checked every six months with a TDS meter, monitor
or probe.
Water should be tested prior to changing the membrane.
When product water is compared to supply (or untreated) water, the water quality
should be improved at least 70%.
Your water treatment professional should check the TDS level during
maintenance calls.