5.1 Lamp Installation and Replacement
WARNING: The lamp heats up after continuous use and can burn your skin if touched. Allow lamp to cool for at least 5 minutes before removing.
DANGER: Do not operate the UV lamp outside of the reactor. The lamp in the unit emits Ultraviolet light that can cause permanent damage to
Never look at the lamp when unit is turned on.
skin and eyes.
Handle the UV lamp by the ends only. Do not touch the bulb of a lamp with your fingers. If the surface of the lamp becomes dirty, use a clean
lint-free cloth to remove the dirt.
Procedure for Replacing / Installing the Ultraviolet (UV) Lamp:
1.
Turn off the water supply at both ends of the system.
2.
Unplug the unit.
3.
Allow at least 5 minutes for lamp to cool.
4.
Remove the connector from the end of the UV lamp.
5.
Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only by the ceramic tips.
6.
Insert the new UV lamp into the quartz sleeve and attach the connector.
7.
Slowly open water supply and check the system for leaks.
Plug in unit and ensure that the UV lamp is operating. A purple glow should be visible through the VuCap ® .
8.
5.2 Cleaning the Quartz Sleeve
Mineral deposits and sediment build-up on the quartz sleeve will affect system performance by decreasing the UV light transmitted through the
quartz sleeve into the water column.
The proper maintenance and replacement of the Sediment and Carbon Block filters supplied with the VPS1140-1 system will reduce the
accumulation of mineral and sediment residue on the quartz sleeve.
The quartz sleeve may be cleaned with a commercially available, non-abrasive, scale remover and a lint free cloth. Cleaning of the quartz sleeve
should be done on a regular basis to ensure maximum system performance. The amount of cleaning required will be dependant upon local
water conditions.
All traces of the cleaning solution must be fully removed from the sleeve before it is reinstalled in the system. Care should be taken to prevent
any cleaning fluid from coming into contact with the inside surface of the quartz sleeve.
Procedure for Removing / Installing the Quartz Sleeve:
1. Turn off the water supply at the inlet valve.
2. Unplug the unit.
3. Drain water from the Stainless Steel UV Chamber.
4. Allow at least 5 minutes for lamp to cool.
5. Rotate VuCap® counter-clockwise to allow for UV lamp removal.
6. Remove the connector from the end of the UV lamp.
7. Remove the UV lamp from the quartz sleeve. Be sure to hold the UV lamp only by the ceramic tips.
8. Remove quartz sleeve retaining nut and O-ring from the quartz sleeve.
9. Remove the quartz sleeve and clean as noted above. A final wipe down with isopropyl alcohol will remove any cleaner residue.
10. Insert quartz sleeve into the UV chamber.
11. Place O-ring onto quartz sleeve and then tighten retaining nut hand tight to ensure a water tight seal.
12. Insert new or old UV lamp into the quartz sleeve and attach the connector from ballast to the UV lamp. Then attach the VuCap®
head to the VuCap® base by turning a quarter turn clockwise.
13. Refill the UV chamber slowly by opening the water supply just enough to fill the chamber with water.
14. Check the system for leaks. If no leaks appear, fully open the inlet water valve.
15. Plug in power to ballast.
16. Ensure that the UV lamp is operating. A purple glow should be visible through the VuCap®