BAttERy REPlAcEmENt
BAttERy mODElS ONly
When the battery weakens, the LED indicator light will blink at a constant
rate when the user's hands are within the sensor range. The battery must be
replaced within two weeks.
tO REPlAcE thE BAttERy:
RONDA N: Carefully open the battery box and remove the old batteries.
Replace the used batteries with six new 1.5V AA batteries. Close the box.
RONDA BOX: Release the screws from the wall cover panel and remove
it. The battery box is located behind the panel. Carefully open the battery
box and replace the used battery with a new 9V battery (Lithium battery is
recommended). Close the box and re-assemble the wall cover panel.
ImPORtANt: These models were supplied with a self adjusting sensor.
The ideal sensor range for the specific location will be set automatically again
after changing the battery.
OBJECT
Check that there are no objects in
front of the sensor after the battery
replacement was completed.
ImPORtANt: Spent batteries should not be disposed of with
normal household waste. Contact your local authority for infor-
mation on waste disposal and recycling.
16
ABOuT
15
SECONDS
After you have replaced the battery,
move away from the sensor range.
15
Wait
seconds in order to allow the
system to set the ideal sensor range.
Then after the self adjustment has
taken place the solenoid valve will be
opened and closed for 1 second as an
indication that the ideal sensor range
was set and the product is ready for
use.
mAINtENANcE
fIltER clEANING INStRuctIONS
These models are provided with a stainless steel filter preventing foreign particles
to enter the lines. It is recommended to clean the filter every six (6) month. If the
water flow has decreased, this may be because the filter is clogged. The filter can
be cleaned as follows:
1.
For Ronda N::
a. Shut-off the water shut off valve.
b. Disconnect the water supply pipe from the adaptor and disassemble the filter.
c. Wash the filter under running water.
d. Reassemble the parts.
e. Restore the incoming water supply and make sure that there is no water
leakage.
2.
For Ronda Box:
a. Release the screws from the wall cover panel and remove it. Turn off the
regulating valve.
b. Disassemble the solenoid valve by opening the nuts.
c. Remove the filter and wash it under running water.
d. Reassemble the filter and the solenoid valve.
e. Turn on the regulating valve and adjust the flow capacity.
f. Make sure there is no water leakage, and re-assemble the wall cover panel.
SOlENOID VAlVE SERVIcING
The solenoid valve diaphragm requires periodical cleaning every six (6) month.
Remove the diaphragm from the solenoid valve and examine it for dirt. in case it
is dirty or clogged, wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with
electronic solenoid valves.
cARE AND clEANING Of chROmE AND SPEcIAl fINIShES
DO NOt use steel wool or cleansing agents containing alcohol, acid, abrasives, or
the like. use of any prohibited cleaning or maintenance products or substances
could damage the surface of the faucet. For surface cleaning of faucet us ONly
soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom
tile, the faucets should be protected from any splattering of harsh cleansers.
If system chemical disinfection is practiced, chlorine can be used (calculated
chlorine concentration of 50mg/l maximum in water per one hour dwell time)
at service interval frequency.
17