OBJ_BUCH-0000000076-003.book Page 8 Monday, September 23, 2019 9:51 AM
en
8
Extension cable.
If the use of an extension cord
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Intended use of the power tool:
Hand-guided hacksaw for commercial use for
cutting round and other shaped work pieces
of metal, plastic and cement in weather-pro-
tected environments using the application
tools and accessories recommended by FEIN.
Operation of the power tool off power generators.
This power tool is also suitable for use
with AC generators with sufficient power
output that correspond to the Standard
ISO 8528, design type G2. This Standard is
particularly not complied with when the so-
called distortion factor exceeds 10 %. When
in doubt, please refer to the generator
instruction/specification guide.
Symbols.
Symbol, character
Explanation
Make sure to read the enclosed documents such as the Instruction Man-
ual and the General Safety Instructions.
Observe the instructions in the text or graphic opposite!
Before commencing this working step, pull the power plug out of the
socket. Otherwise there will be danger of injury if the power tool
should start unintentionally.
Do not touch the saw blade
Use eye protection during operation.
Use ear protection during operation.
Recommended dimensions of extension cords
at an operating voltage of 120 V – single-
phase a. c., with only AStx649-1
(**)/AStxe649-1 (**) connected:
Max. cable length, ft
Max. cable length, m
≤ 100
100
200
–200
–300
Min. conductor size
Min. conductorcross-
A.W.G.
section, mm
16
14
12
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
≤ 30
30
60
– 60
–100
2
1.5
2.5
4