FAN BLOWN MOTORS (U4)
Unimotor fm
Fan Blown
behind fan box
motors (U4)
075
095
115
142
190
Fan blown connector box wiring:
DRIVE SETTINGS
You must ensure that the drive parameters
are set correctly to give adequate thermal
protection to the motor. Please refer to the
motor label when setting the limits for the
drive. The value of the drive parameters will
vary with each type of motor.
Incorrect setting of the current and thermal
time constant (4.15) could cause the motor
to overheat and invalidate the warranty.
20
Clearance
distance
Free air flow
(mm)
40
40
40
50
60
NEUTRAL
EARTH
Fan current
rating
(m
3
/h)
(A)
50
0.05
67
0.05
160
0.08
180
0.07
325
0.13
1
2
LIVE
All
motors
are
commutation preset to match LEROY-
SOMER drives.
Always connect the thermistor wires to the
drive sensor circuits.
Safety and installation - UNIMOTOR FM & HD
Voltage
(Vac)
230
delivered
with
the
4100 en - 2017.08 / c