ASSEMBLY INSTRUCTIONS (CONTINUED)
Assembling the 1600KLScale:
1.
Open the scale to operational position (see scale opening instructions on page 8).
2.
Rotate the display support so that it is perpendicular to the handrail.
3.
Position the display assembly close to the display support on the handrail (see Figure 1,
above). Connect the load cell cable connector to the load cell port on the rear of the display
assembly and insert and secure the cable into the center channel in the display.
NOTE: Do not attach the Power Cord at this point—wait until step 13, below.
4.
Slide the display assembly onto the display support by inserting the two metal supports into
the two slots in the rear display assembly. Tuck the excess load cell cable into the handrail
tube. NOTE: The load cell cable should now be secured in the channel between the display
assembly and the display support.
5.
Insert 4 screws into the display support and tighten.
6.
Connect power cord to the power port in the display assembly and insert and secure the
cable into the exposed portion of the 2nd channel from the left in the display.
7.
Insert the power cord into the retaining slot on the rear cover. Align the rear cover tabs with
the slots on the rear of the display assembly. Apply pressure to snap the rear cover into
place and secure with 2 screws.
8.
Attach the front and small back covers to the display support by applying light pressure.
9.
Gently tip the scale and lie it with handrail on the floor. Twist in the 4 plastic feet assemblies. Do
not tighten.
10. Gently return the scale to the upright position. WARNING: Do not drop the scale on its
feet. This could result in load cell damage.
11. Install the AC adapter holder on the outer left side of the handrail using the 2 screws
attached to the adapter holder assembly.
12.
Attach 2 cable holder clips to the inner left handrail and one underneath the handrail by peeling off
the paper covers from both sides of the adhesive pad and applying to the
handrail. Firmly press the clips on top of the adhesive to secure.
13.
Insert AC adapter into the adapter holder and insert the power cable into the 3 clips on the left side
of the handrail.
14.
Completely screw in all 4 feet (plastic) into the scale base, then turn each foot out a full 2 turns. Make
any necessary adjustments to level the scale by turning the feet in or out as needed.
Figure 2
5