Variation
950 mV
50 mV
Higher than 0°C
Lower than 0°C
CCA
100%
80%
60%
RECHARGE and RETRY
40%
20%
0%
VRLA/GEL/AGM/SLA
STANDARD SLI
Problem
Display does not
switch on
9
Alternator Status Assessment Table
Faulty
Battery Status Assessment Table
Troubleshooting
• Check polarity of clips. The red clip must be connected to the
positive pole, the black clip must be connected to the
negative pole.
• Check good contact between clips and poles.
• Battery voltage may be too low (lower than 9 V)
• Battery voltage may be too high (higher than 18V)
Check black clip connection. Both contacts must be connected to
the pole.
Check red clip connection. Both contacts must be connected to
the pole.
Battery voltage is too low to perform the test. Recharge the
battery and retry.
Battery voltage or charge circuit voltage is too high.
Faulty
OK
Faulty
13.3 V
13.7 V
GOOD & RECHARGE
RECHARGE and RETRY
11.8 V
11.8 V
Remedy
Faulty
15.15 V
15.6 V
GOOD
REPLACE
12.6 V
12.4 V