Technical parameters

Input
Temperature measuring:
Range / accuracy of
temp. measuring:
Outputs
Analog voltage output / rated
current:
Indication of output over-
load:
Communication
Installation BUS:
Status indication unit:
Power supply
Supply voltage / tolerance:
Dissipated power:
Rated current:
Connection
Terminal:
Operating conditions
Air humidity:
Operating temperature:
Storing temperature:
Protection degree:
Overvoltage category:
Pollution degree:
Operating position:
Installation:
Design:
Dimensions and weight
Dimensions:
Weight:
TECHNICAL SUPPORT | E-mail: support@inels.com | Mobil: +420 778 427 366 | Tel.: +420 573 514 276, +420 573 514 211 | Fax: +420 573 514 227 | www.inels.com
Made in Czech Republic
DAC3-04M
YES,
input for external temperature sensor TC/TZ
-20 .. +120°C;
0.5°C from the range
4x 0(1)-10 V/10 mA
red LED OVERLOAD
BUS
green LED RUN
27 V DC, -20 / +10 %
max. 1 W
50 mA (at 27V DC), from BUS
2
2
max. 2.5 mm
/ 1.5 mm
with sleeve
max. 80 %
-20 .. +55 °C
-30 .. +70 °C
IP20 device, IP40 mounting in the switchboard
II.
2
any
switchboard on DIN rail EN 60715
3-MODULE / MODUL
90 x 52 x 65 mm
108 g
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com
Warning
Before the device is installed and operated, read this instruction manual carefully and with full
understanding and Installation Guide System iNELS3. The instruction manual is designated for
mounting the device and for the user of such device. It has to be attached to electro-installation
documentation. The instruction manual can be also found on a web site www.inels.com. Attention,
danger of injury by electrical current! Mounting and connection can be done only by a professional
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations.
Do not touch parts of the device that are energized. Danger of life-threat! While mounting,
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms,
directives and special regulations for working with electrical equipment. Before you start working
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This
instruction manual contains only general directions which need to be applied in a particular
installation. In the course of inspections and maintenance, always check (while de-energized) if
terminals are tightened.
2/2

Publicidad

Tabla de contenido
loading

Productos relacionados para iNels DAC3-04M

Tabla de contenido