NTSTV-DV
0 –10 V-
Ballast or LED Driver Control
Compatible with any LED driver or ballast
that is compliant with IEC 60929 annex E
120 – 277 V~ 50 / 60 Hz
Maximum Capacity
(Limited by whichever is achieved first)
Load 0 – 10 V- Sink
8 A
30 mA
For use with 0 –10 V- Electronic
Fluorescent Dimming Ballasts or
LED Drivers
P/N 0301688 Rev. A
08/2013
Package Contents and Parts Identification
Control Wires
(Violet and Gray)
Control
Wallplate Adapter
Switching Wires
(Black)
Control-Mounting Screws
Adapter-Mounting Screws
Lutron Electronics Co., Inc.
7200 Suter Road
®
Coopersburg, PA 18036-1299 U.S.A. www.lutron.com
Important Notes
Please Read Before Installation
• Wallbox Dimensions: A single-gang wallbox (3 in high × 2 in wide ×
2½ in deep (76 mm high × 51 mm wide × 64 mm deep) will service all
individual controls.
• Derating Instructions: No derating required for multi-gang
installations.
• Wiring Note: Always turn OFF power before installation. Install in
accordance with all national and local electrical codes.
• Lamp Seasoning Requirements: Some fluorescent lamp
manufacturers recommend that new fluorescent lamps be operated
at full output (seasoned) before they can be dimmed, to render lamp
impurities inert, ensuring proper dimming performance and average
rated lamp life. Please contact your lamp manufacturer for seasoning
requirements.
• Ballast/Driver Functionality Check: With power OFF, check new
ballast for functionality prior to installation of control by connecting
the ballast's violet and gray wires together at the control. Turn power
on. The lights should now be at minimum brightness. With power OFF,
disconnect the wires. Turn power ON. The lights should now be at
maximum brightness.
• Cleaning Instructions: Clean dimmer with a soft damp cloth only.
Do not use any chemical cleaners.
• Use this product only as intended with recommended accessories.
Control Unit
Front view
Wire Connectors
Offset-mounting holes
Slider
Wallplate
Center-mounting holes
Pre-Installation
• Determine if this will be a multi-gang installation or a single-gang installation.
• If using a multi-gang installation, before proceeding to the Installation section, follow the Multi-gang Installation
procedure and refer to the instruction sheet supplied with multi-gang wallplates.
• If using a single-gang installation, install control as outlined in the Installation section.
Multi-gang Installation
In multi-gang installations, several controls can be grouped horizontally in one ganging wallbox or in a series of
connected wallboxes. Multi-gang wallplates are available to simplify and improve the appearance of an installation.
For retrofit installations, the side sections can be removed to fit existing wallboxes.
No Side Sections Removed
1. Determine the number of wallboxes necessary by
using the chart below. Use 3 in × 2 in (76 mm × 51 mm)
gangable wallboxes. Do not use plaster rings or gangbox
covers.
Number of Controls
1
2
Wallboxes
1
1 + 1
2. Install or modify appropriate wallboxes. For an EVEN
number of controls, wallboxes must be 3/4 in (19 mm)
apart to provide necessary space for the wallplate(s). For
example, when ganging four controls, three would be
in the four connected wallboxes and one would be in a
wallbox separated by the required space.
Four-gang
gangable
wallbox
3. When mounting controls, use center-mounting holes
Low-end
for first control and offset-mounting holes for additional
trimpot
controls. Allow 1/32 in (0.08 mm) between controls.
shaft
High-end
trimpot
shaft
Side Sections Removed
Note: No derating required
1. One gangable wallbox is needed for each control
in the multi-ganged control. Individually connect
wallboxes or use a pre-assembled, multi-gang
wallbox.
3
4
5
6
2. Remove only inner side sections of control. Use pliers
4
4 + 1
7
7 + 1
to bend side sections down as far as you can then
back to their original positions. Side sections will
break off.
Single-gang
Note: Do not remove outer side sections of the two
gangable
wallbox
controls that are on the ends of the gang.
3. When mounting, use center-mounting holes for
proper alignment.
3/4 in (19 mm)
(use chase nipple)
Multi-ganged
controls,
no side sections
removed
Lutron,
, and Nova T
are registered trademarks of Lutron Electronics Co., Inc.
®
© 2013 Lutron Electronics Co., Inc.
English
Multi-ganged
controls,
inner side
sections
(indicated
by shading)
removed

Publicidad

Tabla de contenido

Solución de problemas

loading

Resumen de contenidos para Lutron NOVA T ntstv-dv

  • Página 1 Center-mounting holes (Black) Control-Mounting Screws Adapter-Mounting Screws Lutron Electronics Co., Inc. 7200 Suter Road Lutron, , and Nova T are registered trademarks of Lutron Electronics Co., Inc. ® ® © 2013 Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 U.S.A. www.lutron.com...
  • Página 2: Troubleshooting

    Notice: Lutron is not liable for damage due to miswiring 0 – 10 V- control signal wires with line voltage. Do not run Class 2 wires and line voltage conductors together in the same conduit.
  • Página 3: Contenido Del Embalaje E Identificación De Las Piezas

    Tornillos de montaje del adaptador Lutron Electronics Co., Inc. 7200 Suter Road Lutron, y Nova T son marcas comerciales registradas de Lutron Electronics Co., Inc. ® ® © 2013 Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 E.U.A. www.lutron.com...
  • Página 4: Instalación

    Aviso: Lutron no se hace responsable por los daños debidos a la conexión incorrecta de los cables de la 10. Monte el adaptador de la placa con los tornillos suministrados. Reemplace el deslizador señal de control de 0 - 10 V- con el voltaje de línea.
  • Página 5: Remarques Importantes

    Vis de montage de l’adaptateur Lutron Electronics Co., Inc. 7200 Suter Road Lutron , et Nova T sont des marques déposées de Lutron Electronics Co., Inc. ® ® © 2013 Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 États-Unis www.lutron.com...
  • Página 6 2 seulement. d’éclairage. Remarque : Lutron n’est pas responsable des dommages liés à un mauvais câblage des fils de signal de 10. Montez l’adaptateur de plaque murale avec les vis fournies. Replacez le variateur et commande de 0 –...
  • Página 7 Parafusos de montagem do adaptador Lutron Electronics Co., Inc. 7200 Suter Road Lutron, , e Nova T são marcas comerciais registradas da Lutron Electronics Co., Inc. ® ® © 2013 Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299, EUA www.lutron.com...
  • Página 8: Resolução De Problemas

    Nota: a Lutron não é responsável por danos causados por conexões elétricas incorretas dos cabos de sinal de controle de 0–10 V- à voltagem de linha. Não use cabos classe 2 e condutores de voltagem de linha no mesmo conduíte.

Tabla de contenido