C A R E RE C O MM E NDAT I O N S
Maintenance
PR O L O NG E D S HU T DO WN
If the ice machine is to be removed from service for an
extended period or exposed to temperatures of 32°F
or below, follow the procedure for prolonged shutdown and
winterization.
Prolonged shutdown and winterization procedure:
Perform the cleaning and sanitizing procedure on page 7
1
to prevent mildew growth.
Disconnect electrical power at the circuit breaker or
2
service panel.
Turn off the water supply.
3
Remove water from the water reservoir.
4
Disconnect the incoming water supply line at the rear of
5
the unit and allow it to drain.
Disconnect the vinyl hose from the water pump and
6
allow it to drain.
Verify water is not trapped in any of the water supply or
7
drain lines. Compressed air can be used to blow out the
lines.
Use a spray bottle with a solution of 1 tablespoon
8
sanitizer to 1 gallon
(3.8 L)
surfaces. Do not rinse, allow it to air dry.
Block the door partially open to provide air exchange
9
and prevent mildew growth.
(0°C)
(15 ml)
water and spray all interior
|
subzero.com
9