Thank you for buying this humidifier. In order to get the most out of it, please read these instructions care-
fully and keep them for future use.
For your safety
VERY IMPORTANT: the following precautions must be taken each time you use an electrical device, especial-
ly when children are present. Make sure you install the humidifier out of the reach of children. Children must
be supervised to ensure that they do not play with the device.
- Check that the voltage shown on the technical specification plate coincides with the voltage in your area.
- Never plug the humidifier in or unplug it if your hands are wet.
- Always place the humidifier on a surface that is flat, level and dry, away from sunlight. Don't place it near to
an air-conditioning unit, electrical devices or wooden furniture during use.
- Never move the humidifier with water inside it while it is operating.
- When the device is switched on, never block the ultrasound output hole.
- Never remove any water remaining in the humidifier while it is still plugged in. You could damage the elec-
trical components.
- Make sure the humidifier is not dropped.
- If the power supply cable is damaged, it should be replaced by the distributor, the distributor's after sales
department or by a similarly qualified person in order to avoid any danger.
- In case of a fault, the humidifier must only be repaired by our after sales department or by a workshop
expressly authorized to do so. You must never open the device yourself.
- Never fill the humidifier via the water output hole.
- If you do not intend using the humidifier for a long period, disconnect it from the mains.
- This device is not designed to be used by people (including children) with reduced physical, sensorial or
mental capacities or people with no experience or knowledge, unless they can benefit, through a person who
is responsible for their safety, from supervision or prior instructions concerning the use of the device.
- Warning: measurement of the humidity and temperature of the room is carried out within a 75 cm radius
around the hygrometer-thermometer.
- Make sure the cold steam outlet nozzle is not facing the hygrometer-thermometer.
Technical details
- Air humidifier.
- Cold steam: no risk of burning.
- Programmable: the humidifier starts and stops
automatically when the programmed level of humidi-
ty is reached.
- Autonomy at maximum output = 10 hours
At minimum output = 20 hours
- Hygrometer-thermometer included, incorporated
Description and use
1 – Adjustable cold steam outlet.
2 – Water reservoir contains 2 litres.
3 – "+" and "-" keys: for programming the desired
level of humidity.
4 - Base.
5 – Hygrometer-thermometer: measures the humidi-
ty level and temperature of the room.
6 – Key Menu
7 – Digital screen.
8 – Nightlight On/Off key.
9 – Humidifier On/Off key.
10 – Power supply indicator.
11 – Nightlight with 7 changing colours.
12 – Reservoir button.
into the humidifier.
- Nightlight with 7 changing colours.
- Cold steam nozzle adjustable through 360°.
- Easy to use.
- Easy to clean.
- Nominal voltage of the device: 220 - 240V
- Power: 32 W
- Frequency: 50 Hz
1
11
10
9
12
8
7
6
• Fill the reservoir 2 after unscrewing the stopper 12. The water falls from the reservoir to the base.
• Retighten the stopper 12 and replace the reservoir 2 on the base 4 and connect to the mains.
• Make sure the hygrometer-thermometer 5 is connected to the humidifier and that it is as far away from the
cold steam outlet as possible.
• Press the switch 9: the humidifier starts until a humidity level of 80% is reached automatically (Default
menu). If you haven't programmed your humidifier, once this level of 80% is reached, the humidifier switches
off.
• Choose the menu you want:
1°) If you press on the "menu 6" once: "Temperature" menu:
on the digital screen 7, the sign "°C" or "°F" starts to flash: you can choose between ° Celsius or Fahrenheit,
by pressing the "+" key.
Confirm your choice by pressing on the "menu 6" twice (no sign should be flashing for this to be confirmed).
2°) If you press "menu" twice: Menu for "programming the desired level of humidity":
7 on the digital screen 7, the sign "set RH" starts to flash:
Program your level of humidity using the "+" and "-" keys.
Once the level of humidity you want is displayed, confirm by pressing 6 on the "menu 6" once ("set RH" stops
flashing).
• Nightlight with 7 colours 10: press nightlight button 8 to switch it on/off.
Cleaning and maintenance:
- Disconnect the device before cleaning it.
- Do not permit water to enter the base. Don't wash the base under the tap or submerge it.
- In order to remove limescale: fill the reservoir with 50% water and 50% white vinegar. Leave to act for 4
hours and rinse three times.
- It is advisable to clean the reservoir once a week with a sponge and dry it with a cloth. Never use soap, deter-
gent, chemical or abrasive products.
- Clean the base with a soft cloth only.
- Leave the device to dry before using again.
- Warning: never use harsh cleaning products. During cleaning, make sure that no water comes into contact
with the electrical components of the device.
Solving common problems:
Problem
The LED power supply indicator is off,
no steam is produced
2
3
The LED power supply indicator is on,
the air is circulating but no, or very little,
steam is produced
The steam has an unpleasant smell.
4
5
WEEE marking – Consumer information.
Disposal of products at the end of their life. You should comply with current legislation
and not dispose of your products with household waste.
Possible cause
The device is not plugged in
Plug the device in and switch it on.
There is no water in the reservoir or
Fill the reservoir, close the lid properly.
the reservoir lid is not shut properly.
Switch the device on by pressing key 9,
The programmed level of humidity is reached.
Demineralization left in the base, the
Clean the base with a cloth, change the
water is dirty or has not been changed
for some time.
Cleaning using soap, detergent, abrasive
Rinse the humidifier with water and dry
or alkaline products.
The water level is too high.
Unplug the device, remove a little water,
close the device and switch it on.
The device is being used for the first
Clean the reservoir, make sure you dry it
time
properly and fill it up again. If the steam
or the water isn't clean.
still has an odour, open the device and
expose it to the air for 12 hours.
Solution