Festo CPV Series Instrucciones Para El Usuario página 26

Valve terminal with as interface
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Type CPV...−GE−ASI−4E4A... M8
Load voltage connection
(only type ...−4E4A−Z)
rated value
(protected against incorrect polarity)
residual ripple
Current consumption for 4 valves
(at 24 V)
when switching on
after current drop (stationary)
Valves (see pneumatics manual)
Digital inputs
design
logic level
reference potential
response delay
AS−Interface data
Profile
26
DC 21.6 ... 26.4 V
4 Vss
CPV10−... CPV14−...
108 mA
42 mA
Watchdog function active
after 50 ms (see 3.4)
4 inputs based on IEC
1131−2 type 2
DC 24 V, PNP, Status dis
play (LED)
ON: 11 ... 30 V
OFF: −30 ...−5 V
0V
typ. 3 ms (at 24V)
ID−Code=F
S−7.F
Festo CPV..−GE−ASI−4E4A−... 0802d English
176 mA
72 mA
;IO−Code=7
H
H

Publicidad

Tabla de contenido