INSTALLATION MANUAL
DGM1D
1-Door Mifare
controller/reader system
®
- Use AC or DC power supply.
- The mawimum distance between
the reader interface and the
controller unit is 50 meters.
With jumper
INTWDGM1
SYT1 wire
1 pair 8/10ème
SYT1 wire
1 pair 8/10ème
Strike
Magnetic lock
Varistor
12 V DC only
(Default configuration)
Cut the strap
12 V AC or 24 V DC
IMPORTANT RECOMMENDATIONS
- DGM1D time lock is programmable
from 2 to 20 seconds with the
PCV123D handheld terminal.
- If using the DGM1D with the reader
interface (INTBUSDGM1), make
sure JP2 jumper is ON.
Without
jumper
26 Bits
44 bits
- Wiegand format must be the same
Between door controller (INTBUSW)
and bus interface (INTW DGM1D)
(Wiegand 26 or 44 bits).
Wire
shielded
EM Input
(Door status)
EN
Reader format must be
Identical to controller
format INTBUSW
Without jumper
without clock
INTBUSW
With jumper
with clock
Standalone or
integrated mode
(Refer to
INTBUSW
manual)
SYT1wire
shielded
To th next reader
controller