FIG. E: SOLUTION FLOW GUIDE
1. Light
Solution
Vacuum
slots
SERVICING
The Upholstery Pro is designed to allow easy in-
the-field service to the glide and the trigger
valve with basic hand tools in just a few
minutes. If replacement becomes necessary,
rebuild kits and replacement parts are available
from your Sapphire distributor or from Sapphire
Scientific at 800-932-3030.
Replacing the glide
Have on hand a Glide and O-ring replacement
kit (part no. S13-01705).
1. Remove the four cover screws (Fig. B, 3)
and lift off the cover.
2. Remove the four glide screws (Fig. B, 5)
and remove the glide and the O-ring seal. Discard.
3. Install new O-ring into sealing edge of new glide. Put
new glide into head. Make sure that the O-ring is in
place.
4. Replace glide screws and tighten; then replace
cover and tighten with cover screws.
Servicing the trigger valve
If the trigger leaks or no longer releases sufficient
solution and you have determined that the glide is not
plugged or damaged (see "Check Glide Assembly," p. 2)
the trigger may need service. Two repair options are
available.
Option A: Rebuild the trigger valve.
A stem replacement kit (part no. 48-064) is available
from your Sapphire distributor. The parts included in this
kit are shown in Fig. F.
1. Remove the nut and bolt from the trigger lever and
remove the lever.
2. Unscrew stem retention nut and lift out stem
assembly.
3. Install the stem assembly and retighten the stem
retention nut.
4. Replace cover and reinstall trigger lever. Use the
new lock nut provided (Fig. F, 3).
Option B: Replace the trigger valve assembly
A replacement trigger valve assembly (part no. 23-070)
is available from your Sapphire distributor.
07-01713B 2010-05
2. Medium
FIG. F: STEM REPLACEMENT KIT (48-064)
3. Trigger lever lock nut
8. Shoulder screw
1. Remove the four cover screws (Fig. B, 3) and lift off
2. Depress the hose release ring on the solution outlet
3. Remove the solution outlet tube fitting from the valve
4. Disconnect the solution inlet hose assembly from the
5. Valve body and trigger will now drop free.
6. Insert new trigger valve valve assembly and reinstall
7. Replace cover.
REPLACEMENT PARTS
The following replacement parts are available from your
Sapphire Scientific distributor:
Description
Trigger and valve body
Glide and O-ring seal
Strainer, 50 Mesh
Orifice
Washer
Stem replacement kit
3
3. Maximum
1. Stem retention nut
2. Stem.
Periodically
apply grease
6. O-ring seal
7. Extractor spring
the cover.
tube and pull out the tube. Avoid kinking the tube.
body.
valve body.
solution outlet tube and solution inlet hose
assembly.
Drawing
reference
Fig. B, 4
Fig. B, 6
Fig. D, 2
Fig. D, 4
Fig. D, 5
Fig. F
4. O-ring seal
5. Teflon seal
Replacement
part no.
23-070
S13-01705
20-006
20-035
24-002
48-064
Sapphire Scientific