OPERATING INSTRUCTIONS
COIN
INTER
SLOT
PROTECTIVE
CASING
COIN BOX
INSTALLATION
WARNING: The installation and assembly of electrical equipment must be carried out
by an authorized installer.
- Open the top cover and insert the conductors thought the drillhole provided for this
purpose.
- Connect the conductors to the terminal strip following the scheme shown in figure 1.
Terminals 1 and 2 are for power supply and are marked L (live) and N (neutral).
Terminals 3 and 4 correspond to the timing circuit and terminals 5 and 6 to the early
warning circuit.
- Connect the earth wire to the terminal indicated for this purpose.
The appliance is internally protected from interference by means of a safety circuit.
Nevertheless, some especially strong electromagnetic fields may affect its operation.
Interferences may be avoided if the following installation instructions are followed:
- The equipment should not be installed close to inductive loads.
- It is advisable to provide a separate line for the power supply (if necessary provided
with a network filter).
- Inductive loads must be provided with interference suppressors (varistor, RC filter).
PROGRAMMING
IMPORTANT: PROGRAMMING MUST BE CARRIED OUT WITH THE APPLIANCE
DISCONNECTED FROM THE MAINS VOLTAGE.
All the programming is carried out by means of the device situated at the upper part of
the electronic circuit shown in figure 2.
The "CTM ELECTRÓNICO" is provided with 4 mini-switches known as SW1, SW2,
SW3 and SW4, two of which are rotary (SW1 and SW4) and the other two sliding.
Each one is responsible for the functions explained below.
MINIMUM NUMBER OF COINS: Switch SW1 is used to indicate the number of coins
with which the operation of the timing circuit starts.
UNUSED
HOURS
NORMAL TIMING (SW2)
POSITION
(SEE TABLE)
Nº OF COINS (SW1)
SW1
RESET (SW7)
0 1
9
8
2
7
3
SW7
6
4
5
For instance, it is wished that the user of the installation has to insert 4 coins in order
for it to start operating. Turn SW1 until it indicates the number 4.
COIN OR TOKEN OPERATED TIME METER
DISPLAY
CONNECTION
STRIP
1
2
3
4
5
6
L
N
EARTH CONNECTIO
TEMPORIZACIÓN
PREAVISO
FIXTURE
DRILLHOLES
CABLE APERTURE
FIG. 1
NORMAL TIMING (SW3)
(SEE TABLE)
HOURS
POSITION
LONG EARLY
WARNING POSITION
Nº OF COINS FOR
SPECIAL TIMING (SW4
SW2
SW3
SW4
ON
ON
0 1
9
8
2
SHORT EARLY
7
3
6
4
1
2
3
4
5
6
1
2
3
4
5
6
5
WARNING POSITION
MINUTES
POSITION
MINUTES
POSITION
FIG. 2
TIMING TIMES: The timing time corresponding to each coin is established by the 5
first switches of SW2 or SW3. The 4 switches situated more to the left configure a
timing value and the fifth makes this value signify hours or minutes (ON = hours, OFF
= minutes). The value will be given by the combinations shown in the following table:
POSITION
VALUE
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
RESET: The RESET button initializes the programme of the "CTM ELECTRÓNICO"
and stores the present configuration. AFTER PROGRAMMING THE APPLIANCE THE
RESET BUTTON MUST BE PRESSED.
PAUSE: The pause function is used to temporarily stop timing without loss of memory.
The appliance enters this status when the pause terminals are disconnected and
remains in this status until their contacts become short-circuited again. This opening of
the circuit can be achieved either by means of a switch or by means of a potential-free
relay, see figure 3. IN ORDER TO AVOID MEMORY LOSS IN THE APPLIANCE IT
MUST BE RECEIVING POWER SUPPLY.
SPECIAL TIMING: Switch SW4 indicates the number of coins by which the timing
passes from normal timing (configured in SW2) to special timing (configured in SW3).
To achieve maximum special timing it is necessary to insert all the coins one after
another. Setting SW4 to 0 deactivates special timing.
EARLY WARNING: Switch 6 of SW3 is used to select the duration of the early warning
activated prior to the end of timing.
ON - Long early warning. 4 minutes before the end of the timing the early warning
circuit will be connected for 30 seconds.
OFF - Short early warning. 30 seconds before the end of the timing the early
warning circuit will be connected for 10 seconds.
N. MINIMO
IC8
DE MONEDAS
R1
SW7
SW1
C6
C7
C5
IC2
C4
R2
IC7
X1
C8
R3
IC6
POTENTIAL - FREE
CONTACT
JP1
PAUSE
TERMINALS
D5
D3
D6
C12
D7
L1
L2
C11
C13
ADJUSTMENT OF TYPE OF COIN:
The type of coins to be used can be modified by the user following these steps:
- Change the coin insert slot (External plate)
- Loosen the screws in order to be able to move parts A and B (see fig. 4).
- Move parts A and B until the desired coin diameter is obtained
- Fasten to screws to fix the desired position.
(B)
FIXING SCREW
SLIDING GUIDE
PIVOTS
FIXING SCREWS
(A)
CTME
POSITION
1
OFF
OFF
OFF
ON
2
ON
OFF
OFF
ON
3
OFF
ON
OFF
ON
4
ON
ON
OFF
ON
5
OFF
OFF
ON
ON
6
ON
OFF
ON
ON
7
OFF
ON
ON
ON
8
ON
ON
ON
ON
ARR1
N.MONEDAS
SW2
SW3
T.ESPECIAL
SW4
T.ESPECIAL
PREAV.
T.NORMAL
IC3
DISPLAY1
C10
IC4
SW5
C9
C3
D2
D1
D8
C2
D4
C1
IC1
BR1
F1
FIG. 3
TR1
FIG. 4
COIN DIAMETER
VALUE
9
10
15
20
30
45
90
150