Technical Specifications - Perel FT15N Manual Del Usuario

Cañon calefactor a gas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
14.
Troubleshooting
problem
The motor does not work.
The pilot light does not burn.
The pilot light dies out seconds
after being ignited.
The flame dies out while the
heater is switched on.
The pilot light has bright and
yellow spots.
15.

Technical Specifications

IP rating
power
air flow
gas pressure
power supply
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device. For more info concerning this
product and the latest version of this manual, please visit our website www.perel.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
V. 03 – 24/03/2017
FT15N
cause
Faulty power cable.
Faulty motor.
Faulty switch.
There is no spark.
Low gas level.
Faulty gas valve.
Closed security valve.
Disordered thermocouple.
The valve has been insufficiently
activated.
Faulty thermocouple or valve.
Overheated device.
Insufficient gas feeding volume.
The device is overheating.
Faulty air feeding at the burner.
Excessive gas flow toward the
burner.
IPx4D
17500 W
300 m³/h
500 mbar
230 V, 50 Hz
Replace or repair.
Replace or repair.
Replace or repair.
Adjust the distance between the
electrode and the burner or
replace the burner.
Replace the gas cylinder.
Replace or repair.
Press the button to activate the
security valve.
Adjust the thermocouple according
to the burner.
Repeat the switch-on procedure.
Replace or repair.
Leave the heater to cool down for
5 minutes before switching on.
Replace the gas cylinder.
Insufficient airflow toward the
heater. Ventilate the room in
which the heater is being used.
Free the airflow toward the heater
or ventilate the room in which the
heater is being used.
Check the pressure and/or replace
the pressure regulator on the gas
cylinder.
7
solution
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido