Since 1956
Changing Character Display
To change character(s) displayed:
1. Place round end (silver) of earth magnet (Fig. 1)
against lens, over "Unlock" symbol (Fig 2).
After 1-2 seconds, the display will sequence through
available characters.
2. When desired character is displayed, remove mag-
net. The character will be retained in memory until it is
changed again with magnet.
3. Repeat for each character (IDX-2 and IDX-3).
Available characters and their sequence:
-, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9,_, T, 1(on the right side), "Test
function" (all LEDs on), "Off Function" (all LEDs off).
Sequence begins at "-" unless unit's character was
previously changed.
Mount Holes For All Models Of IDX Are 12mm Deep, For Screw Size M8 X 1.25
24 Inch (60.96 cm) Harness Included.
Pinout Shown Is For Harness Connector
3-Pin Deutsch
Pinout
DT 04-3P
IDX Identification Displays
IDX Mount Guide and Connection
Fig. 1
Fig. 2
Risk of electric shock.
Disconnnect all sources of
supply prior to installation or
service.
Place this end
against lens over
lock symbol.
Magnet Included