Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Enlaces rápidos

FOCUS MOTOR
For SCT & EDGEHD
#94155 - Setup Guide
The focus motor is compatible with all Celestron SCTs from
6" to 14" in aperture that have been produced since the year
2006; it is not compatible with 5" SCTs or older models. It is
also compatible with all EdgeHD telescopes, the RASA 8,
and the Celestron 7" Maksutov-Cassegrain.
This setup guide will guide you through installation and
basic operation of the focus motor. The full instruction
manual can be downloaded from the focus motor page at
celestron.com.
PARTS LIST
1. Focus Motor Assembly
2. Cover Plate, 6" through 9.25" Fig.1
3. Cover Plate, 11" & 14" Fig.2
4. Adapter Sleeve
5. Adapter Sleeve Screw
6. Set Screw
7. AUX Cable
8. Hex Key
9. Wrench
10. Screwdriver
INSTALLATION
1. Remove the rubber cover from the telescope's focuser
knob. If you cannot simply pull it off, use a fl at head
screwdriver or other tool to pry off the rubber cover.
2. Loosen and remove the 3x screws on the cover plate of
the focuser.
3. Carefully remove the cover plate.
4. Identify which one of the two supplied cover plates is for
your size optical tube as indicated in the parts list.
5. Orient the new orange cover plate for your size optical tube
as shown below.
6" and 7"
8" and 9.25"
11" and 14"
6. Reuse the 3 screws previously removed to install the
new orange cover plate in place of the old one.
7. Check to see if the arrow indicator on the motor housing is
pointing within the "range" marking on the rear of the motor
coupling. If it isn't, rotate the motor coupling using the
supplied wrench as shown until the arrow points within the
range. This allows access to the motor coupling's clamping
screw after the motor is installed on the focuser.
Fig.1
Arrow Indicator
8. Loosen the focus motor's clamping screw a few turns
Fig.2
using the supplied hex key.
9. FOR 6" THROUGH 9.25" TELESCOPES ONLY:
Install the adapter sleeve into the focus motor. Use
the supplied adapter sleeve screw to secure the
sleeve.
Adapter
Sleeve
10. FOR 6" THROUGH 9.25" TELESCOPES ONLY:
Install the set screw into the threaded hole in the focus
motor's clamping collar using the supplied hex key. Do
not tighten the set screw yet, only thread it in a few
turns.
11. Place the focus motor onto the brass focuser knob.
Orient the motor as shown below. Make sure the two
captive screws in the focus motor line up with the two
holes in the orange cover plate as shown.
Range Marking
Clamping
Screw
Adapter Sleeve Screw
Set Screw
Captive
Screws
Hex Key
12. Use the provided hex key to tighten the 2 captive screws.
Alternate between tightening each of the screws until
they are fully engaged with the cover plate.
13. FOR 6" THROUGH 9.25" TELESCOPES ONLY::
Tighten the set screw that was installed in step 10. If you
need to rotate the motor coupling to gain better access
to the set screw, use the wrench as indicated in step 7.
14. Tighten the focus motor's clamping screw using the hex
key until fully tightened. If you need to rotate the motor
coupling to gain better access to the clamping screw,
use the wrench as indicated in step 7.
Clamping Screw
NOTE: If the focus motor interferes with camera installation, the motor
mounting orientation can be rotated. This can be done by using the other
mounting holes in the cover plate's perimeter (step 11), or by rotating the
entire cover plate (step 5).
POWERING THE FOCUS MOTOR
There are three ways to power the focus motor:
1. Use a Celestron computerized mount. Connect the AUX
port on the focus motor to an AUX port on the mount using
the supplied cable.
2. Use a USB3 port or a USB2 port that provides at least
900 mA. Connect the focus motor with a USB A-to-B
cable (not included). Use a high quality cable, or the
motor may not receive enough power.
3. Use a DC power source able to supply at least 1A. Connect
the power source to the 12V DC jack on the focus motor
using a 5.5mm/2.1mm cable that is tip positive.
CONTROLLING THE FOCUS MOTOR WITH A
CELESTRON HAND CONTROLLER
If using a Celestron mount and plugged into an AUX port,
the focus motor can be controlled from the mount's
hand controller. Either the NexStar+ hand controller
(requires fi rmware version 5.30+) or the StarSense
hand controller (requires fi rmware version 1.19+) can
be used. If your fi rmware is not up to date, use the
Celestron Firmware Manager (CFM) program available at
celestron.com/CFM to update it. The link will
download the program automatically. The focus motor
controls can be found in the hand controller by pressing
the MENU button and selecting "Focuser. "
Holes in
Cover Plate
Hex
Key

Publicidad

loading

Resumen de contenidos para Celestron 94155

  • Página 1 6” and 7” CONTROLLING THE FOCUS MOTOR WITH A CELESTRON HAND CONTROLLER If using a Celestron mount and plugged into an AUX port, the focus motor can be controlled from the mount’s hand controller. Either the NexStar+ hand controller (requires fi rmware version 5.30+) or the StarSense hand controller (requires fi rmware version 1.19+) can...
  • Página 2 FRANÇAIS CONTROLLING THE FOCUS MOTOR WITH A COMPUTER If using a Celestron mount and plugged into an AUX port, connect the hand controller to the computer using a USB A-to-mini B cable (not included). One end of the cable is...
  • Página 3 5,5 mm/2,1 mm qui est de pointe positive. CONTRÔLER LE MOTEUR DE MISE AU POINT AVEC UN CONTRÔLE À MAIN DE CELESTRON Si vous utilisez un monture Celestron et que vous avez Vis de fi xation Vis de fi xation branché...
  • Página 4 FOKUSSIERMOTOR FÜR SCT UND EDGEHD #94155 - Einrichtungsanleitung 20,32 cm (8”) und 23,5 cm (9,25”) Der Fokussiermotor ist mit allen Celestron SCTs von 15,24 cm (6”) bis 35,56 cm (14”) Blendenöffnung kompatibel, die Einstellschraube Einstellschraube seit dem Jahr 2006 hergestellt werden; er ist mit 12,7 cm (5”) 11.
  • Página 5 Il motore per fuoco è compatibile con tutti gli SCT COMPUTER Celestron da 6” a 14” di apertura che sono stati prodotti dal 2006; non è compatibile con SCT da 5” o modello più Wenn Sie eine Halterung von Celestron verwenden und vecchi.
  • Página 6 CONTROLLO DEL MOTORE PER FUOCO CON UN CONTROLLER MANUALE CELESTRON Se si usa un supporto Celestron e si collega una porta AUX, il motore per fuoco può essere controllato dal Vite di regolazione controller manuale del supporto. Può essere usato sia il controller manuale NexStar+ (richiede versione 11.
  • Página 7 #94155 - Guía de instalación El motor de enfoque es compatible con todos los STC de Celestron de 6» a 14» de apertura que se hayan fabricado desde el año 2006; no es compatible con STC de 5» Tornillo de fi jación Tornillo de fi...
  • Página 8 5,5mm/2,1mm con punta positiva. CONTROLAR EL MOTOR DE ENFOQUE CON UN CONTROLADOR MANUAL CELESTRON Si usa un soporte Celestron conectado a un puerto AUX, el motor de enfoque puede controlarse con el controlador manual del soporte. Puede usar el controlador manual NexStar+ (precisa de firmware versión 5.30+) o el...