Dimensions; Eyewash Installation - Bradley S19-788H Manual Del Usario

Tanque de 15 galones con lavaojos y camisa calentadora
Ocultar thumbs Ver también para S19-788H:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Dimensions

44¼"
(1124mm)
1
Eyewash installation — S19-788H
Remove the plastic dust plug from the bottom of the yoke
assembly and discard.
B
Attach the pressure gauge to the adapter
on the pressure side of the tank with
pipe sealant (by installer) .
NOTICE: When attaching the pressure
gauge to the tank inlet, hold the
adapter (item 3) with a wrench to
prevent stripping. Failure to do so
may damage the seal and cause
leakage. Max. torque 150 in-lbs.
Bradley • 215-1416 Rev. U; ECN 18-05-033
34¼"
(870mm)
14"
(356mm)
6"
(152mm)
37⁵⁄₈"
(956mm)
Attach the eyewash yoke assembly to the
tank . Max . torque 150 In-Lbs . (The excess
heater cable from the yoke assembly will
A
be tucked into the heater jacket in a later
step .) Route the power cable through the
tank handle .
NOTICE: Check to ensure the heat trace
cable from the yoke assembly is not
kinked or damaged from assembly.
9/10/2018
S19-788H
3