Wireless test

The following test should only be performed after the Wireless Basis
has performed the first-open function, when the switch output is not
active any more.
The Wireless test should be performed prior to the wall installation in order to
exclude possible sources of disturbance. Press the SET button of the thermostat
in order to test the assignment of the thermostats or the wireless transmission.
The zone assigned to the Wireless Basis will be switched for 1 minute, independ-
ent from the current state of operation.
If the Wireless Thermostat cannot be assigned or if the assigned zone cannot
be switched during the Wireless test, the reception conditions for the base are
unfavourable. An external receiver AB EX 4070 can be supplied optionally for
this case.