NoStress rotor settings selected
Press the ↓ or ↑ buttons once or twice at any time to visualise the rotor settings for
the selected NoStress option:
Example option 1 below:
Minimum RPM: below 1875 rpm the feed roller stops.
Return RPM: from 2175 rpm, the feed roller starts to turn.
Normal RPM: after over-speed of the engine or rotor (PTO), the rotor must return
to less than 2175 rpm in order that the feed roller can function again.
RPM overspeed: rotor stops.
REMINDER:
It is formally forbidden to modify the default factory settings of the Pilot System. Any
modification to the security and program parameters made outside of our factories is
the entire responsibility of the person having made these changes.