Back Tamper Terminal Wiring

If you wish to use the back tamper (recommended) remove the short from the back tamper
terminal block and connect the back tamper wires to the back tamper terminal block.

DIP Switch Settings

DIP 1: LED operation
On: LED enabled
Off: LED disabled
DIP 2: PIR detection sensitivity
On: High
Off: Normal
DIP 3: Walk test mode
On: Alarm (every 3 Sec.)
Off: Alarm delay (every 2.5 Min.)
Note:
For Walk test, DIP 3 must be set to ON and then
set back to OFF for normal operation

Detection Range Adjustment

Slide the moving PIR to the desired
position, see figure 6.
The range of the lower detection area
determines the detection range.
The upper PIR is fixed and its detection
area is parallel to the ground at all times.
The lower detection area changes from
2m to 12m depending on the location of
the moving PIR. Therefore, the detection
range is established according to the
location of the lower PIR since both the
upper and the lower PIR should be
triggered in order to activate an alarm.
BACK TAMPER