Polygroup SUMMER WAVES ST1100 El Manual Del Propietario
Polygroup SUMMER WAVES ST1100 El Manual Del Propietario

Polygroup SUMMER WAVES ST1100 El Manual Del Propietario

Ocultar thumbs Ver también para SUMMER WAVES ST1100:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

SUMMER WAVES
SAND FILTER PUMP
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
For any setup and troubleshooting issues, please visit
support.polygroupstore.com Customer Service: (888)919-0070
DO NOT RETURN PRODUCT TO STORE
Should you encounter a problem with your Polygroup
to Polygroup
. Prior to contacting Customer Service, please first review the Troubleshooting Guide in the Installation Manual, or review the FAQ and instructional
®
videos at support.polygroupstore.com. If you are still unable to correct the problem, please contact Polygroup
product type, model number and your purchase receipt ready, so that our Customer Service Representative can assist you in resolving the problem. You may be asked
to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup
Polygroup
Trading Limited, (hereinafter "Polygroup
®
workmanship for 180 days from the date of purchase. Original Purchaser must retain proof of such purchase in the form of an original store sales receipt
and must produce such upon request by Polygroup
This Limited Warranty applies only to the original purchaser of the product and is limited solely to the repair or replacement of the product, to be decided
in Polygroup
's sole discretion. Consequential damages, including claims for loss of water, pool chemicals, damage, or labor are not covered under this
®
Limited Warranty. This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by unauthorized persons; use
non-Polygroup
parts or accessories with the product; use the product in contravention of the manufacturer's Instructions; use improper voltage; abuse
®
the product in any way; or through accident or negligence. Normal wear-and-tear is not covered under this Warranty, nor are acts of God outside the
control of Polygroup
. Polygroup
®
manufacturing defect. IN NO EVENT SHALL Polygroup
THE BUYER OR ANY OTHER PARTYFOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or other jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
FOR ABOVE GROUND SWIMMING POOLS
ST1100 (10") / ST1600 (12") models
Product, please DO NOT return the product to the place of purchase. All Warranty claims must be made directly
®
LIMITED WARRANTY
") warrants to the original purchaser only, the Sand Filter Pump against defects in material and
®
or its designated agents. Warranty claims cannot be processed without a valid proof of purchase.
®
will not be held responsible for grasses that may grow through the ground cloth and/or pool liner, as this is not a
®
, THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO
®
DISTRIBUTED BY: Polygroup
Unit 606, 6th Floor, Fairmont House, No.8 Cotton Tree Drive, Central, Hong Kong
OWNER'S MANUAL
To order parts and accessories,
please visit www.polygroupstore.com
customer service at (888) 919-0070. Please have the
®
without a Return Merchandise Authorization number.
®
Trading Limited
®
®
Manual#
09C3A4USA013

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Polygroup SUMMER WAVES ST1100

  • Página 1 Customer Service Representative can assist you in resolving the problem. You may be asked to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup without a Return Merchandise Authorization number.
  • Página 2: Tabla De Contenido

    TABLE OF CONTENTS Warnings ................................. 3 ~ 6 Preliminary Steps, Pump Power Information & Part List ................. 7 ~ 8 Setup Instructions ............................9 ~ 13 Use Of Pump ..............................14 ~15 Pump Motor Care & Pump Maintenance ......................16 Pool Water Care ..............................
  • Página 3: Warnings

    CUSTOMERS THAT PURCHASE POOLS MAY BE REQUIRED BY LOCAL OR STATE LAW TO INCUR ADDITIONAL EXPENSES WHEN INSTALLING A POOL, IN ORDER TO COMPLY WITH STATE OR LOCAL LAWS REGARDING FENCING AND OTHER SAFETY REQUIREMENTS. CUSTOMERS SHOULD CONTACT THEIR LOCAL BUILDING CODE ENFORCEMENT OFFICE FOR FURTHER DETAILS. POLYGROUP IS NOT RESPONSIBLE FOR ANY ADDITIONAL EXPENSES THAT YOU MAY INCUR.
  • Página 4 Turn on the pump for the recommended hours daily. If you are unsure of the time frames please refer to support.polygroupstore.com for the recommended Pump Operation Hours based on pool types and sizes. Clean and replace filter cartridge frequently. Replace only with genuine Polygroup / Summer Waves Brand filter cartridge.
  • Página 5: First Aid

    OWNER’S MANUAL First Aid 1. Keep a working phone and a list of emergency numbers near the pool. 2. Become certified in cardiopulmonary resuscitation (CPR). In the event of an emergency, immediate use of CPR can make a lifesaving difference. Special Warning 1.
  • Página 6: Installer Responsibilities

    ASME American Society of Mechanical Engineers Two Park Avenue, New York NY 10016-5990 Contact: 800-843-2763 (U.S. & Canada) 973-882-1170 (outside North America) www.asme.org NSPI National Spa and Pool Institute (see APSP) UL Underwriters Laboratories 333 Pfingsten Road,Northbrook IL 60062-2096 Contact: 877-854-3577 or 847-272-8800 www.ul.com NSF NSF International P.O.
  • Página 7: Preliminary Steps, Pump Power Information & Part List

    5. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC) “Swimming Pools, Fountains and Similar Installations” or its latest approved edition. 6. The ST Series Sand Filtration Systems are manufactured by Polygroup and ETL control number 4000608 and 4006317 - double insulated and grounded - ®...
  • Página 8 Sand Specifications: Fill the tank with #20 silica sand ONLY. You can purchase the sand from your local home improvement or building material stores. WARNING: Using the incorrect sand may damage the filtration system and will void the warranty. RETURN FITTING SET SUCTION FITTING Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8AM to 5PM MST, Monday-Friday.
  • Página 9: Setup Instructions

    OWNER’S MANUAL SETUP INSTRUCTIONS Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. WARNING: CLIMBING HAZZARD! PLEASE PREVENT CHILDREN FROM CLIMBING ON THE FILTRATION SYSTEM TO GAIN ACCESS TO THE POOL. Tools required: Flat-blade screwdriver (not included) 1.
  • Página 10 6. With the Drain Valve of the Sand Tank pointing outwards, 5. Insert and push the Lock Pins all the way down to place the Sand Tank onto the Sand Tank Base secure the Pump to the Sand Tank Base PUSH Drain Valve ALIGN...
  • Página 11 OWNER’S MANUAL 9. Fill the tank with #20 silica sand ONLY. You can purchase the 10. Remove the Sand Guard and save for future use. sand from your local home improvement or building material stores. Slowly pour sand into the Sand Tank until the sand level is between the Min and Max marks on the Center Pipe Sand...
  • Página 12 12. Place the Clamp around the flange of the 6-Port Valve 13. Close the Clamp by pushing the two jaws as close together and Sand Tank as possible. IMPORTANT: Align the hinge on the Clamp with the ridge on the flange of the 6-Port Valve PUSH The hinge of Clamp aligned with the ridge of 6-Port Valve...
  • Página 13 OWNER’S MANUAL 16. When the Clamp is tightened and no more turns can be 17. Connect the Short Hose between the Pump Outlet and the made, flip and push the Cam Handle towards the Sand Tank 6-Port Valve Inlet. Tighten the Hose Clamps with a flat-blade to secure.
  • Página 14: Use Of Pump

    USE OF PUMP Before using the Pump IMPORTANT: 1. Make sure to press the pump power switch to OFF before plugging the GFCI Power Cord Set into a power outlet. Do NOT connect the Set to a timer device. 2. Always PRESS DOWN the 6-Port Valve Handle BEFORE switching handle positions.
  • Página 15 OWNER’S MANUAL Operation Instructions 1. Make sure the pump is switched OFF. 2. Plug the GFCI Power Cord Set to a grounded receptacle at least 15 feet (4.5m) away from the pool. Press the RESET button to start the pump. 3.
  • Página 16: Pump Motor Care & Pump Maintenance

    PUMP MOTOR CARE IMPORTANT! This Sand Filter Pump is protected by a thermal switch, a safety device that stops the pump from running when it's overheated, to prevent pump damage and prolong service life. If your pump turns off automatically, it’s likely the pool water temperature is too high or the water flow through the pump is insufficient for cooling the pump down.
  • Página 17: Troubleshooting Guide

    OWNER’S MANUAL TROUBLESHOOTING GUIDE WARNING: TURN OFF THE PUMP AND UNPLUG THE POWER CORD BEFORE TROUBLESHOOTING THE FILTER PUMP. Problem Cause Solution A. The Pump not plugged in OR the GFCI A. The GFCI Set must be plugged into a grounded power outlet. Then Power Cord Set not activated press the RESET button to start the Pump.
  • Página 18: Replacement Parts Ordering Info

    REPLACEMENT PARTS ORDERING INFO ST1100 ST1600 ST1100 ST1600 Key# Description Key# Description PART # PART # PART # PART # P58PP2884A09 P58PP1782E09 P58PF8950E09 P58PF8950E09 Sand Tank Base 6-Port Valve Handle P58PP2884G8U P58PP1782G8U P58PF8950G8U P58PF8950G8U Sand Tank SF Gasket (black) P58000001W05 P58000000W05 P58PF1520K01 P58PF1520K01...
  • Página 19: 6-Port Valve - Parts List & Setup

    OWNER’S MANUAL 6-PORT VALVE PARTS LIST Wrench Locking Ring Valve Handle Valve Gasket Top Cover O-Ring Pressure Gauge Drain Outlet Window Valve Housing Drain Outlet Window O-Ring Valve Grate Valve O-Ring Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8AM to 5PM MST, Monday-Friday. Extended operating days and hours during peak season requirements.
  • Página 20 6-PORT VALVE SETUP 1. Using the Wrench, twist counterclockwise to loosen and remove the Locking Ring. 2. Fit the Gasket in place. 3. Insert the Top Cover O-Ring into the groove of the Valve Housing. Top Cover O-Ring Valve Gasket Valve Housing Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8AM to 5PM MST, Monday-Friday.
  • Página 21 OWNER’S MANUAL 4. Insert the Valve Handle into the Valve Housing. Make sure that the key aligns with the keyway. 5. Place the Locking Ring over the Valve Housing. 6. Tighten the Locking Ring with the Wrench. Locking Ring Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8AM to 5PM MST, Monday-Friday. Extended operating days and hours during peak season requirements.
  • Página 22: Asme Compliant Suction Fitting Info

    OWNER’S MANUAL ASME COMPLIANT SUCTION FITTING INFO PSF-100A and PSF-100B Suction Outlet Fitting (For Aboveground Pool) 1. PSF-100A and PSF-100B Suction Outlet Fitting are certified by IAPMO in accordance with the ASME/ANSI/APSP/ICC-16 2011 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. 2.
  • Página 23: Bomba Filtrante De Arena Summer Waves

    / o el revestimiento de la ® ® piscina, ya que esto no es un defecto de fabricación. EN NINGÚN CASO SERÁN RESPONSABLES Polygroup , SUS AGENTES AUTORIZADOS, ENTIDADES ®...
  • Página 24 ÍNDICE Advertencias ..............................3 ~ 6 Pasos Previos, Información Sobre La Potencia De La Bomba Y Lista De Piezas ......... 7 ~ 8 Instrucciones De Montaje ..........................9 ~ 13 Uso De La Bomba ............................14 ~15 Cuidados Del Motor De La Bomba Y Mantenimiento De La Bomba .............. 16 Ratamiento Del Agua De La Piscina ......................
  • Página 25: Advertencias

    ADICIONALES AL INSTALAR UNA PISCINA, EN CUMPLIMIENTO DE LAS LEYES ESTATALES O LOCALES RELATIVAS AL VALLADO Y OTROS REQUISITOS DE SEGURIDAD. LOS CLIENTES DEBEN PONERSE EN CONTACTO CON LAS AUTORIDADES LOCALES CORRESPONDIENTES PARA MÁS INFORMACIÓN. POLYGROUP NO ES RESPONSABLE POR GASTOS ADDICIONALES QUE PUEDAN OCCURIR.
  • Página 26: Sistemas De Circulación

    Limpie y cambie el cartucho de la bomba del filtro con frecuencia. Reemplazar solo con un cartucho de filtro original de la marca Polygroup...
  • Página 27 MANUAL DEL USUARIO filtro de la bomba debe colocarse de manera que no pueda ser usado por los niños pequeños como medio de acceso a la piscina. No deje juguetes dentro de la piscina al terminar de usarla, ya que los juguetes y objetos similares podrían atraer a los niños a la piscina. 3.
  • Página 28: Sistemas De Filtración

    APSP Association of Pool & Spa Professionals (formerly National Spa and Pool Institute) 2111 Eisenhower Avenue, Suite 500 Alexandria VA 22314-4679 Contacto: 703-838-0083 www.apsp.org ASME American Society of Mechanical Engineers Two Park Avenue, New York NY 10016-5990 Contacto: 800-843-2763 (U.S. & Canada) 973-882-1170 (outside North America) www.asme.org NSPI National Spa and Pool Institute (see APSP) UL Underwriters Laboratories...
  • Página 29: Pasos Preliminares

    5. Todos los componentes eléctricos deberán instalarse de acuerdo con el artículo 680 del Códico Eléctrico Nacional, “Piscinas, fuentes e instalaciones similares” o su última edición aprobada. 6. Los sistemas de Bomba de filtrado de arena serie ST están fabricados por Polygroup y el número de control ETL es el 400468 y el 46317 - doble aislamiento y ®...
  • Página 30: Especificaciones De La Arena

    Especificaciones de la arena: Llene el depósito con arena de sílice #20 SOLAMENTE. Puede adquirir la arena en su comercio local de materiales para el hogar. ADVERTENCIA: El uso de arena incorrecta puede dañar el sistema de filtración y anulará la garantía. ACCESORIO DE RETORNO ACCESORIO DE SUCCIÓN Si tuviera algún problema, llame al Servicio al cliente al número (888) 919-0070 de 8:00 a 17:00 (MST)
  • Página 31: Instrucciones De Montaje

    MANUAL DEL USUARIO INSTRUCCIONES DE MONTAJE Antes de montar el producto, dedique unos minutos a revisar el contenido y familiarícese con todas las piezas. ADVERTENCIA: COLOQUE ESTE PRODUCTO APARTADO DE LA PISCINA A FIN DE EVITAR QUE LOS NIÑOS SE SUBAN A ÉL Y ACCEDAN A LA PISCINA. Herramientas necesarias: Desarmador de punta plana (no incluido) 1.
  • Página 32: Válvula De Desagüe

    5. Inserte y presione las pasador de bloqueo hasta el fondo 6. Con la válvula de desagüe en el depósito de arena apuntando hacia fuera, instale el depósito de arena en la base del para fijar la bomba a la base del depósito de arena depósito de arena (PRESIONAR) PRESIONAR...
  • Página 33 MANUAL DEL USUARIO 9. Llene el depósito con arena de sílice #20 SOLAMENTE. Puede 10. Remueva la guardia de arena y consérvela para adquirir la arena en su comercio local de materiales para el hogar. futuros usos. Lentamente, eche arena en el depósito de arena hasta que su nivel quede entre las marcas Min y Max en la pipa central Sand...
  • Página 34 12. Coloque la abrazadera alrededor de la pestaña de la válvula 13. Cierre la abrazadera presionando las dos mandíbulas tan de 6 puertos y del depósito de arena cerca una de la otra como sea posible. IMPORTANTE: Alinie la bisagra a la abrazadera con cresta de a válvula de 6 puertos PRESIONAR...
  • Página 35 MANUAL DEL USUARIO 16. Cuando la abrazadera esté apretada y no pueda girar más, 17. Conecte la manguera corta entre la salida de la bomba y la dele vuelta y presione el mango de la abrazadera hacia el entrada de la válvula de 6 puertos. Apriete las abrazaderas de depósito de arena para fijarlo.
  • Página 36: Uso De La Bomba

    USO DE LA BOMBA Antes de usar la bomba IMPORTANTE: 1. Asegúrese de presionar el interruptor de encendido de la bomba hacia la posición OFF (apagado) antes de conectar el conjunto del cable de alimentación GFCI al tomacorriente. NO conecte el conjunto a un dispositivo temporizador. 2.
  • Página 37 MANUAL DEL USUARIO Instrucciones de funcionamiento 1. Verifique que la bomba está apagada. 2. Enchufe el conjunto del cable de alimentación GFCI a un receptáculo conectado a tierra a una distancia mínima de 15 pies (4,5 m) de la piscina. Presione el botón de REINICIO para poner la bomba en funcionamiento.
  • Página 38: Cuidados Del Motor De La Bomba Y Mantenimiento De La Bomba

    NUNCA eche a la piscina trozos o gránulos de productos químicos. Esto puede presentar un peligro para los bañistas y/o dañar el revestimiento. 3. Limpie la piscina regularmente con una aspiradora eléctrica de manguera de jardín de Polygroup o de un almacén de productos para piscina.
  • Página 39: Guía De Resolución De Problemas

    MANUAL DEL USUARIO GUÍA DE RESOLUCIÓN DE PROBLEMAS ADVERTENCIA: DESENCHUFE EL CABLE DE ALIMENTACIÓN ANTES DE SOLUCIONAR CUALQUIER PROBLEMA EN LA BOMBA DE FILTRACIÓN. Problema Causa Solución A. La bomba no está enchufada O el conjunto del A. El conjunto GFCI debe estar enchufado a un tomacorriente con toma de tierra. A cable de alimentación GFCI no está...
  • Página 40: Desmontaje Y Almacenamiento De La Bomba De Arena

    INFORMACIÓN SOBRE PEDIDOS DE PIEZAS DE REPUESTO ST1100 ST1600 ST1100 ST1600 Nº Llave Description Nº Llave Description N.º DE PIEZA N.º DE PIEZA N.º DE PIEZA N.º DE PIEZA P58PP2884A09 P58PP1782E09 P58PF8950E09 P58PF8950E09 Mango de la válvula Base del depósito de arena de 6 puertos P58PP2884G8U P58PP1782G8U...
  • Página 41: Válvula De 6 Puertos - Lista De Piezas E Instalación

    MANUAL DEL USUARIO LISTA DE PIEZAS DE LA VÁLVULA DE 6 PUERTOS Llave Aro de cierre Mango de la válvula Junta de la válvula Cubierta superior del anillo de cierre Manómetro Ventana de la salida del desagüe Carcasa de la válvula Aro de la ventana de la salida del desagüe Rejilla de la válvula...
  • Página 42 LISTA DE PIEZAS DE LA VÁLVULA DE 6 PUERTOS 1. Con una llave, gire en sentido antihorario para aflojar y retirar el aro de cierre. 2. Coloque la junta en su lugar. 3. Inserte el aro de la cubierta superior en la ranura de la carcasa de la válvula.
  • Página 43 MANUAL DEL USUARIO 4. Inserte el mango de la válvula en la carcasa de la válvula. Compruebe que la llave está en línea con la línea de llave. 5. Coloque el aro de cierre sobre la carcasa de la válvula. 6.
  • Página 44: Información Sobre La Conformidad Asme Del Accesorio De Succión

    MANUAL DEL USUARIO INFORMACIÓN SOBRE LA CONFORMIDAD ASME DEL ACCESORIO DE SUCCIÓN PSF-100A y PSF-100B Orificio De Salida De Succión (Para Piscinas Sobre Suelo) 1. Los orificios de salida de succión PSF-100A y PSF-100B tienen la certificación de la IAPMO de acuerdo con la norma ASME/ANSI/APSP/ICC-16 2011 Accesorio de succión para piscinas, piscinas infantiles, spas y bañeras de hidromasaje.

Este manual también es adecuado para:

Summer waves st1600

Tabla de contenido