ENGLISH
1) INSTALLATION INSTRUCTIONS
2) P7300 XL Flush valve DN20 -G3/4"
3) EN 12541 compliant
4) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully bleed the pipes that can damage the mechanisms or water passages (PRESTO® heads that can be
dismantled from front). Recommended operating pressure according to NF EN 816: 1 to 5 bar.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water. Abrasive, acid, alkaline or ammonia-based household products are prohibited.
5) Ref. 55514 – FLUSH TAPVALVE P7300 XL MAINS POWER SUPPLY FOR CROSS-PARTITION
6) Technical characteristics:
Electronic detection module
- 1 stainless steel front plate with automatic or manual control
- 1 fastening kit
Hydraulic module
1 flush tapware and solenoid valve with shut-off valve.
- Connection male thread G3/4"
- 1/4 turn stop valve
- Automatic flow regulator.
- Outlet connector for 28x2 dia. PVC tube (ref. 47850).
Transformer (not supplied)
Installation on DIN rail
- For 1 to 3 valves (18VA) Ref. 90464
- For 4 to 6 valves (35 VA) Part no. 90711
- For 7 to 10 valves (75 VA) Ref. 90610
In IP 65 waterproof case
- For 1 to 3 valves (18VA) Ref. 90685
- For 4 to 6 valves (35 VA) Ref. 90704
- For 7 to 10 valves (75 VA) Ref. 90686
7) Detection area
8) 350 to 450 depending on flap
9) Flush tube Ref. 47850 not supplied
10) Installation of P7300 XL
11) Bleed the installation before installing the valve
12) White tube - Dia. 4 - Length = 1 m
13) Connect on inlet arrow
14) Green or black tube connection
15) Connect on outlet arrow
16) 1 - Install the green or black tube as shown on the diagram 2 - Install the white tube
17) Green or black tube - Dia. 4 - Length = 1 m
18) Power cord, 12V- AC
19) Flow rate diagram
20) Flow rate (l/s)
21) Pressure (bar)
22) Operating mode
23) Manual button
24) Display LED
25) - Continuously lit
26) - Rapid flashing
27) - Slow flashing
28) - Series of flashes (1 to 4 flashes)
29) PRESTO electronic WC flush valve offers both automatic and manual operation
30) Manual mode:
- Pressing the manual control triggers a 6 litres flush. - When the user leaves, the automatic mechanism is disabled, so the flush is not activated.
31) Automatic mode (if manual push mode is not used)
After 15 seconds' presence, the system is activated. The flush is triggered 2s after the end of user detection. If the presence time is less than 60s, the system automatically
triggers a 6l flush. If it is in excess of 60s, the system triggers a standard flush (6l or 9l depending on the selected programme).
32) Automatic flush: A 6l automatic flush is carried out every 72 hours.
33) Available programmes
The valve has four operating programmes.
It is supplied with programme 1
Programme no.
1
2
3
4
Volume selection: Depends on bowl used
Range selection: The standard range provides proper operation for most installations.
However, in highly reflective or confined spaces, the short range option may be required to prevent reflection from doors or walls disrupting proper operation of the product.
34) 60-second water flow shutoff to allow maintenance
35) Changing the active programme
36) Holding the reflector in front of the cell causes the valve to flash slowly and shuts off water flow – it then starts flashing quickly (at which point the reflector should be
withdrawn).
The number of flashes emitted by the tap corresponds to the number of the active programme.
37) Programme no.
38) Programme + 1
39) New Programme no.
40) Each time the reflector is passed in front of the cell, the LED lights up and the programme no. is increased by one step. (1,2,3,4, 1,2,3,4, 1,2,3,4, etc.), confirmed by a number
of flashes corresponding to the new programme.
If the reflector is not presented again, the LED emits 5 series of flashes corresponding to the new programme no. and the valve returns to service.
During the first minute after powering on, or during the 60-second shutoff, or during programme changes, the central LED lights up during detection enabling the user to see
how far the detection range extends
41) MAINTENANCE
42) In the event of an anomaly, remove the cartridge and rinse in clean water
43) Spare parts – Cartridge class II
- P1000 XL TC hydro-electronic discharge - Ref. 90931
- S P1000 XL TC Trigger
44) Replacing the cartridge
45) P1000 XL TC discharge Ref. 90931
46) Cartridge + seals Ref. 01272
47) Foolproof location of cartridge in body
48) Foolproof location of seal in cartridge
49) S P1000 XL TC Trigger replacement - Ref. 90829
50) Disassembly
51) Reassembly
52) Respect the connection of tubes according to the diagram on page 3
53) Replacing the sensor circuit – Ref. 90918
54) For proper operation of the sensor tapware, avoid installing these products facing a mirror or any other reflective surfaces. Do not install 2 sensor taps facing one another.
55) This document is not contractual; we reserve the right to modify the characteristics of our products without notice.
56) PATENTED and REGISTERED MODELS
Wash volume
9l
6l
9l
6l
- Ref. 01272
- Ref. 90829
Detection range
Standard (approx. 900 mm for white background)
Standard (approx. 900 mm for white background)
Short (approx. 700mm for white background)
Short (approx. 700mm for white background)