Frequently asked questions
The control board does not work any more using
the hand-held transmitter, only with the switch and
even then only as long as a button is pressed and
kept pressed.
Open with push-button (1) or CLOSE with push-
button (2)
The unit does not close automatically, it
OPENS automatically
Control board does not work with hand-held
transmitter
Gate can only be opened
The control board is not running
The wing does not open completely for the soft
stop
(Remote controlled) universal receiver does
not work
A declaration of conformity for completely constructed gate units in accordance with machine directive 98/37/EC or
EN13241-1 to be handed over to the user of the unit is available on request under the number 114A3152-GTO.
1.Dip switch setting not as desired
2.A safety photocell, a contact strip or the
stop disables the control board
3.Only one photocell was connected for
OPEN
The motor cables are not connected correctly
1.Hand-held transmitter not
programmed
2.An photocell blocks
1.photocell blocks
2.Dip switch setting not as desired
No covered distance learned
1.Insufficient force in the event of high
wind loads
(entire gates)
2.Gate sluggish/heavy
Observe polarity (terminals 14/15)
D e c l a r a t i o n o f c o n f o r m i t y
The undersigned declares that the device listed complies with the directives and
standards mentioned below.
Model: ....................................................................................................................CB22
EN55014, EN61000-3, EN61000-4, ETS 300 683, EN 300 220-3, EN60335-1,
EN60335-2-103 and EN13241-1
• 89/336/EEC
• 73/23/EEC
• 1999/5/EC
S t a t e m e n t o f t h e m a n u f a c t u r e r
As long as the electric control board CB22 is installed or maintained in combination with
an external gate drive in accordance with all manufacturer instructions, it complies with
the specifications of machine directive 89/392/EWG.
B.P. Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
October, 2005
© Chamberlain GmbH 2005, all rights reserved
1.Correction of the dip switch,
elimination of fault required. If the fault
cannot be repaired, it will be necessary
to "reset" and reprogram (see photocell)
2.At least one photocell must be
connected and activated for CLOSED
or OPEN & CLOSED.
The motor cables (brown,black) must be
swapped
1.Program hand-held transmitter
2.Check photocells
1.First limit switch gate OPEN
Function and connection of the limit
switches must be checked
2.Check dip switch
Learn covered distance.
See Initial operation
1.Reset force ( increase )
2.Improve ease of movement
3.Program control board without soft
stop
Swap "+" and "-" cables
709421C