INSTALLATION MANUAL
CA-A460-P - CA-A460-PNB
Relay Expansion Module
Figure 2: Serial Cable Connection
CT-V900-A

3] JUMPER SETTINGS

As shown in Figure 3, there are 5 jumpers on the
CA-A460-P which set some of the module's opera-
ting modes.
Figure 3: Jumper Location
1A/125V
E-BUS
EOL jumper /
B- High/Low jumper /
cavalier EOL /
cavalier haute/basse polarisation B- /
Puente RFL
Puente B- Superior/Inferior
A+ High/Low jumper /
cavalier haute/basse polarisation B+ /
Puente A+ Superior/Inferior
EOL JUMPER
Place the EOL jumper ON when the CA-A460-P is at
the beginning (Start Point) or at the end (End Point)
of the E-Bus network. Otherwise, place the jumper
OFF. See Figure 4.
HIGH/LOW BIAS JUMPERS
Sets
the
impedance
either
HIGH
or
LOW
Set
both
jumpers
normally. Setting the impedance to LOW raises
the DC level and should only be used in advanced
installations. See Figure 4.
ADR JUMPER
Used in multiple relay expansion installation types,
CA-A460-P
RLY jumper /
cavalier RLY /
Puente RLY
ADR jumper / cavalier ADR /
Puente ADR
of
the
RS-485
(default
=
HIGH).
to
HIGH
when
running
this jumper sets the addresses of the modules.
Set the fi rst module's ADR jumper to ON to set
the module's address to Expander 1. A module
with an address of Expander 1 recognizes the
on-board relays as relays 3-9 when connected to the
CT-V900-A controller. Set the second module's
jumper to OFF to set the module's address to
Expander 2. A module with an address of Expander 2
recognizes
the
10-16 when connected to the CT-V900-A controller.
See Figure 4.
RLY JUMPER
Reserved for future use.
Figure 4: Jumper Settings
CTV-900-A
CA-A460-P
#1
EOL Jumper / Cavalier EOL /
Puente RFL:
EOL / RFL = OFF / NON INSTALL...
High/Low Jumpers /
Cavaliers haute/basse polarisation /
Puentes Superior/Inferior:
A+ = HIGH / HAUTE / SUPERIOR
B- = HIGH / HAUTE / SUPERIOR
ADR Jumper / Cavalier ADR /
Puente ADR:
ADR = ON / INSTALL...
Set all jumpers to OFF whenever resetting
the controller.
CA-A460-P Specifications
Communication
Power
Current
Output
to
on-board
relays
as
Start Point / point de départ / Punto Inicial
End Point / point final / Punto Final
CA-A460-P
#2
EOL Jumper / Cavalier EOL /
Puente RFL:
EOL / RFL = ON / INSTALL...
High/Low Jumpers /
Cavaliers haute/basse polarisation /
Puentes Superior /Inferior:
A+ = HIGH / HAUTE / SUPERIOR
B- = HIGH / HAUTE / SUPERIOR
ADR Jumper / Cavalier ADR /
Puente ADR:
ADR = OFF / NON INSTALL...
RS-485 (max. distance of 1220m / 400ft.)
12Vdc
60mA (420mA maximum)
8 Relay Outputs
(Form ìCî Rela y - 5A 30Vdc Resistive)
www.cdvi.com