Installation
Instructions
■ Check with your local public works department
for plumbing codes. You must follow these guidelines
as you install the Water Filtration system.
■ Use the Water Filtration system on a potable, safe-to-drink,
home COLD water supply only. The filter cartridge
will not purify the water or make it safe to drink.
■ DO NOT use on a hot water supply. Cold water supply only
(40-100° F).
■ Install or store where it will not be exposed to temperatures
below freezing or exposed to any type of weather. Water
freezing in the system will damage it.
■ Your Water Filtration system will withstand up to 125 pounds
per square inch (psi) water pressure. If your house water
supply pressure is higher than 100 psi, install a pressure
reducing valve before installing the Water Filtration system.
REQUIRED TOOLS FOR INSTALLATION
■ Phillips screwdrivers
■ Pliers
■ Adjustable wrench
REQUIRED PARTS FOR INSTALLATION
3/8" Tubing (Pex or Plastic)
2-3/8" NPT Fittings
Teflon Tape
®
2-3/8" Nuts
2 Tube Inserts
Sump Wrench - UCWRNCH
This GX1S01R is Tested and
Certified by NSF international
against NSF/ANSI Standard 42
for materials and structural
C
US
integrity requirements and
COMPONENT
against CSA B483.1.
SAFETY PRECAUTIONS
49-50247-1
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
Water Filtration System
GX1S01R
WARNING:
is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used
on disinfected water that may contain filterable cysts.
Discard all unused and packaging material after installation.
Small parts remaining after installation could be a choke hazard.
OPTIONAL KITS AND TOOLS FOR INSTALLATION
NOTE: Sump wrench (UCWRNCH) and faucet (UNFCTBL)
are sold separately for model GX1S01R.
■ Drill and 1/4" bit (saddle valve installation)
■ Drill and drill bit for 3/4" hole (type as required)
if mounting hole is needed for faucet
■ Pipe cutter
■ File
CAUTION:
To avoid damaging the sink, consult a
qualified plumber or installer for drilling procedures. Special
drill bits may be needed for porcelain or stainless steel.
JR 10-08
1
Do not use with water that

Publicidad

Tabla de contenido
loading

Resumen de contenidos para General Electric GX1S01R

  • Página 1 • Sump Wrench - UCWRNCH This GX1S01R is Tested and Certified by NSF international against NSF/ANSI Standard 42 for materials and structural integrity requirements and COMPONENT against CSA B483.1. 49-50247-1 JR 10-08 GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225...
  • Página 2: Installation Options

    5. Allow cold water to run until air is removed from water. NOTE: Sump wrench (UCWRNCH) and faucet (UNFCTBL) ″ are sold separately for model GX1S01R. Mounting bracket to wall Outlet The bracket can be used as a template for marking...
  • Página 3: Flush Procedure

    FLUSH PROCEDURE Whenever water of unknown quality is passed through The procedure for flushing the GE Water Filtration system is: the GE Water Filtration system, filter elements should See Filter Cartridge Installation or Replacement section be discarded and the filtration system flushed. and follow steps 1, 2, 3 and 4.
  • Página 4: Parts List

    PARTS LIST General Electric Parts Catalog REF. NO. PART NO. PART DESCRIPTION WS28X10063 MOUNTING BRACKET WS31X10026 HOUSING HEAD WS03X10038 O-RING, SUMP HOUSING WS20X10007 SUMP HOUSING WS02X10057 MOUNTING SCREWS *NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve.
  • Página 5: Système De Filtration D'eau

    OUTILLAGE NÉCESSAIRE POUR L’INSTALLATION PIÈCES ET OUTILS OPTIONNELS POUR L’INSTALLATION ■ Tournevis Phillips NOTE : Les produits suivants sont vendus séparément pour le modèle GX1S01R : clé pour corps de filtre (UCWRNCH) ■ Pince et robinet (UNFCTBL). ■ Clé réglable ■...
  • Página 6: Options Pour L'installation

    Tube 5. Laisser couler l’eau froide jusqu’à ce que l’air soit éliminé de l’eau. NOTE : Pour le modèle GX1S01R, la clé pour corps de filtre (UCWRNCH) et le robinet (UNFCTBL) sont vendus séparément. Sortie d’eau...
  • Página 7: Méthode De Purge

    MÉTHODE DE PURGE Chaque fois que le système de filtration GE est exposé à de l’eau Méthode de rinçage du système de filtration GE : de qualité inconnue, on devrait jeter les éléments de filtration Voir la section Cartouche de filtration – Installation et rincer le circuit.
  • Página 8: Liste Des Composants

    LISTE DES COMPOSANTS Catalogue des pièces General Electric DE RÉF. DE PCE DESCRIPTION WS28X10063 SUPPORT WS31X10026 TETE DE LOGEMENT WS03X10038 JOINT CIRCULAIRE, LOGEMENT DE CARTER DE VIDANGE WS20X10007 LOGEMENT DE CARTER DE VIDANGE WS02X10057 VIS DE SUPPORT *NOTE : Dans l’État du Massachusetts, les codes en vigueur exigent que cet équipement soit installé...
  • Página 9: Sistema De Filtración De Agua

    PARA LA INSTALACION PARA LA INSTALACION ■ Destornilladores Phillips NOTA: Llave inglesa (UCWRNCH) y llave de agua (UNFCTBL) se venden separadamente para el modelo GX1S01R. ■ Alicates ■ Taladro punta de 1/4″ (instalación de válvula ■ Llave ajustable tipo montura) PIEZAS REQUERIDAS PARA LA INSTALACION ■...
  • Página 10: Opciones De Instalacion

    NOTA: Llave inglesa para receptáculos (UCWRNCH) y ″ llave de agua (UNFCTBL) son vendidas separadamente para el modelo GX1S01R. Salida Instalacion de la abrazadera a la pared del gabinete Abrazadera La abrazadera puede ser usada como modelo para de montaje marcar la ubicación de los tornillos de montaje.
  • Página 11: Procedimiento De Lavado

    PROCEDIMIENTO DE LAVADO Cada vez que agua de calidad desconocida pasa a través El procedimiento para lavar el sistema de Filtración de Agua GE es: del sistema de Filtración de Agua GE, el elemento del filtro debería Vea la sección Instalación y Reemplazo del Cartucho del Filtro ser deshechado y el sistema de filtración lavado.
  • Página 12: Lista De Partes

    LISTA DE PARTES Catálogo de partes de GE REF. NO. PARTE NO. DESCRIPCION DE LA PARTE WS28X10063 CONSOLA DE MONTAJE WS31X10026 CABEZA DE LA CUBIERTA WS03X10038 ANILLO O, CUBIERTA DEL COLECTOR DE ACEITE WS20X10007 CUBIERTA DEL COLECTOR DE ACEITE WS02X10057 TORNILLOS DE MONTAJE *NOTA: Los códigos del estado de Massachusetts requieren que la instalación sea hecha por un plomero licenciado y no permite el usa...

Tabla de contenido