Noise Level - OmarLift C40 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating instructions for
MINILIFT PUMP UNIT C40 - C50
1,5
Ø Rod
[mm]
50
0,10
60
0,06
70
0,05
80
0,04
85
0,03
90
0,02
CT-2-40*
0,11
*CT-2-40 : Stage telescopic cylinder
Ø Rod (mm)
Max. rod
stroke (m)
TANK TYPE
C40
C50
NOISE LEVEL : Max 62 dba at 1 meter distance in standard test conditions (*).
(*) As confi rmed by the measurement made in the room "TEST OMARLIFT"
The manufacturer reserves the right to make changes without prior notice!
CONTROL UNIT TYPE: MINILIFT V1 – V2
12
16
1,5
1,8
11
11
13
55
45
53
0,13
0,09
0,07
0,05
0,04
0,03
0,14
50
60
C40
14,5
9,7
C50
20,5
13,7
TANK CAPACITY
(Liters)
41
53
23
1,5
1,8
2,2
11
14
16
32
40
45
0,19
0,14
0,10
0,075
0,065
0,043
0,21
Table 1
70
80
7,6
5,7
10,7
8,2
Table 2
MIN. OIL LEVEL
(Liters)
12
12
Table 3
Page:
D846M5L.008
Date of Issue:
14/03/2012
Version:
Approved:
Pump [l/min.]
Motor [kW]
[A] Power consump. mono-phase
Max. static pressure [bar]
Piston speed
[m/s]
85
90
CT2-40
5,1
4,5
15,9
7,3
6,4
22,5
USABLE OIL
(Liters)
29
41
Rev. 02
UT

Publicidad

Tabla de contenido
loading

Productos relacionados para OmarLift C40

Este manual también es adecuado para:

C50

Tabla de contenido