Safety Notes; Operating Conditions; Technical Data - Grohe TECTRON 37 419 Manual Del Usuario

Ocultar thumbs Ver también para TECTRON 37 419:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
GB

Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable for
indoor use.
• The 230 V connecting wire must not be fed into the cistern
and the switched-mode power supply must not be installed
in the cistern.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Operating conditions

®
Bluetooth
version 4.0.
The current version of the app required for using the system
must be installed on the control unit in advance.
The required App is available for free in the iTunes Store
(requires an Apple account) and the Google Play store
(requires a Google account), see fold-out page I.
For operation under adverse environments, in buildings /
rooms with reinforced concrete walls, steel and iron frame, or
near of obstructions (eg furniture) of metal, the Bluetooth
reception can be disturbed and interrupted.
Type of obstructions
Interference or shielding
potential
Wood, Synthetic
Low
material
Water, Bricks, Marble
Medium
Plaster, concrete,
High
glass, solid wood
Metal
Very high
The Bluetooth® adaptor operates in a frequency band of
2.4GHz. The installation near devices with the same frequency
band (eg wireless devices, DECT phones, etc. (observe
manufacturer documentation)) should be avoided.

Technical data

• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption
®
Bluetooth
:
• Power consumption:
• Output:
®
• Bluetooth
- version:
®
• Bluetooth
- Transmission distance:
(depending on the environments)
3
• Wait time after flushing
• Minimum delay (2 – 10 s, adjustable)
• Detection zone according to Kodak Gray Card,
grey side, 8x10", landscape:
• Type of protection
- Fitting
- switched-mode power supply
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This work
must be carried out in accordance with the
regulations to IEC 60364-7-701 (corresponding to
VDE 0100 Part 701) as well as all national and local
regulations.
Only water-resistant round cables with max. outside
diameter of 6.0 to 8.5 mm may be used.
Installation
The minimum installation depth must be adhered to if
the water connection is installed on the rear of the
cistern, see fold-out page I.
Make sure that the servo motor and electronic module
from the same packaged unit are installed (calibrated
at the factory).
A vacant tube is required for the line between switched-
mode power supply and electronics, see fold-out page I.
Plaster and tile the wall, excluding the area of the
structural shell protection.
Operation,
see technical product information, 99.0409.xxx /
99.0438.xxx.
Flushing can also be manually initiated and interrupted
by pressing the button.
Activating setting mode
4 W
Disconnect the power supply to the electronics and reconnect
after 10 s.
1 W
The indicator lamp in the sensor system illuminates in setting
®
Bluetooth
- Class 2
mode when the detection zone of the fitting is reached by an
approaching user.
4.0
Setting mode is automatically terminated after 3 minutes.
about 10m
, see fold-out page I.
, see fold-out page II - III.
5 s
5 s
75 cm
IP 59K
IP 55
A
2
2500 V
100 °C

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tectron 37 504

Tabla de contenido