Interface INWMPMHI001R000
Safety instructions
WARNING
Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may
damage seriously the interface and/or the AC indoor unit.
• This interface must be installed by accredited technical personnel (electrician, installer or authorized technical personnel) and
following all the safety instructions.
• This interface must only be installed in a restricted access location.
• Before manipulate the AC indoor unit be sure it is completely disconnected from Mains power.
• In case of installation of the interface inside the AC indoor unit, fix the interface and communication cables preferably to any
appropriate point of the plastic cover of the unit taking care of no blocking free movement of mobile parts and as far as possible
from tubes containing liquids and power cables.
Installation instructions
1. Unplug the Mitsubishi Heavy Industries system from mains electricity.
2. Connect Intesis device RC port to Mitsubishi Heavy Industries indoor unit XY terminals (no polarity on RC connector).
3. Connect Wired Remote Control in parallel to XY bus (if present).
4. Configure the Intesis switches (see below).
5. Plug the Mitsubishi Heavy Industries system to mains electricity.
1. Wi-Fi Access Point or Router
2. Intesis device
3. Wired Remote Controller
4. Indoor unit
1
Switch configuration
Binary value
Switches
Decimal
b
...b
value
1 2 3 4
0
4
0xxx
0
 x x x
1xxx
1
 x x x
x0xx
0
x  x x
x1xx
1
x  x x
xx0x
0
x x  x
xx1x
1
x x  x
xxx0
0
x x x 
xxx1
1
x x x 
SW3: This switch determines the performance of the device. Running in High Performance Mode means maximum consumption and maximum device performance.
SW4: This switch determines the Wi-Fi range of the device. Maximum range is set by default. Consider that changing this switch may affect to device WiFi communication,
happening a device in a running installation not to reach the current access point or Wi-Fi network to which is connected.
In case no external supply is used: In very specific installations, AC port consumption may be overpassed, leading the device to reboot. If that happened, decrease device
consumption by using SW3 and SW4.
NOTE: Remember that you need to power cycle the climate system or the Intesis device for the changes in the switches to be applied.
The User's Manual is available at:
https://intesis.com/products/ac-interfaces/daikin-gateways/mitsubishi-heavy-ascii-wifi-vrf-mh-rc-wmp
Rev.1.0
© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
Important: If a wired remote controller of the AC manufacturer is connected in the same bus, communication may shut down. In
case it happens, use an external power supply connected to the PS connector in our device to overcome this situation.
Connect a NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply to the device, respect the polarity.
Apply always a voltage within the range admitted and of enough power (12V DC, min. 100 mA).
Description
Slave - A Mitsubishi Heavy Industries remote controller must be present in XY bus configured as Master (Default value)
Master – Mitsubishi Heavy Industries remote controller not needed in XY bus. If it exists, it must be configured as Slave
Temperature in Celsius (in the RC bus) (Default Value)
Temperature in Fahrenheit (in the RC bus)
Low Power Mode
High Performance Mode (Default value)
Wi-Fi power is limited
Max Wi-Fi power (default value)
4
2
Installation Manual
connector
OPTIONAL
3
XY BUS
URL
https://www.intesis.com
1 / 2
XY

Publicidad

loading

Resumen de contenidos para Intesis INWMPMHI001R000

  • Página 1 In case no external supply is used: In very specific installations, AC port consumption may be overpassed, leading the device to reboot. If that happened, decrease device consumption by using SW3 and SW4. NOTE: Remember that you need to power cycle the climate system or the Intesis device for the changes in the switches to be applied. The User’s Manual is available at: https://intesis.com/products/ac-interfaces/daikin-gateways/mitsubishi-heavy-ascii-wifi-vrf-mh-rc-wmp...
  • Página 2 1. Desconecte el sistema de Aire Acondicionado de la alimentación. 2. Conecte el puerto RC de Intesis a los terminales XY de la unidad interior Mitsubishi Heavy Ind. (sin polaridad en RC). 3. Conecte el Control Remoto Cableado de forma paralela al bus XY (si existe).