FireHawk
QUICK REFERENCE GUIDE
The FireHawk M7 I-HUD (Internal Heads-Up Display), located in the
Ultra Elite
or Ultra Elite XT Facepiece allows a user to see cylinder
®
pressure in regular pressure remaining increments, PASS pre-alarms,
battery status, and telemetry information (optional) while wearing
the air mask.
The FireHawk M7 I-HUD is compatible with FireHawk M7XT/M7 Air Masks
only.
Approved* HUD Transmitter
FireHawk M7XT Control Module
FireHawk M7 Control Module
*Model number is located on the back of the I-HUD Transmitter.
NOTE: This quick reference guide provides user instructions for
the FireHawk M7 I-HUD receivers. Refer to the appropriate user
manual for complete instructions pertaining to FireHawk M7
I-HUD use.
User Instructions
FireHawk M7XT Air Mask
FireHawk M7 Air Mask
FIREHAWK M7 I-HUD FUNCTIONALITY
1. The I-HUD allows the user to see the cylinder pressure while
wearing the air mask. The transmitter wirelessly transmits a signal to
the I-HUD (in the facepiece) while the air mask is in use. The I-HUD
displays the cylinder pressure in regular cylinder increments, by an
LED pattern.
• As each cylinder pressure increment is reached, a unique LED
pattern will be displayed for approximately 20 seconds before
extinguishing. The display can be refreshed by pressing the
mode button on the transmitter (green on the FireHawk
M7XT/M7 Control Module) approximately three seconds.
• When the End-of-Service-Time Indicator (EOSTI) service
pressure is reached (33% for FireHawk M7XT, 25% for all
others), a single flashing red LED will be displayed and will
continue to flash until the unit is turned off or the cylinder is
refilled.
• The I-HUD must be within approximately 18 inches of the I-HUD
Transmitter to properly receive the signal being transmitted.
2. The I-HUD has a buddy light that flashes red when the air mask
reaches the EOSTI. This buddy light is not visible to the user while
the air mask is in use.
For More Information, call 1-877-672-3473 (MSA-FIRE) or Visit Our Website at www.MSAsafety.com
CRANBERRY TWP., PENNSYLVANIA, U.S.A. 16066
MSA 715 (L) Rev. 4
M7 I-HUD
®
7-2719-1
7-2183-1
10128861
10082858
3. When the user of the air mask remains motionless for
approximately 20 seconds, the PASS pre-alarm (if an integrated
PASS is in use) will begin to sound. During this pre-alarm, the I-HUD
will display an orange LED, and this LED will extinguish when full
PASS alarm is reached or the pre-alarm is reset.
4. When an evacuation command is sent to the user (if an optional
telemetry module is in use), the I-HUD will display an alternating red
and orange LED until the evacuation is confirmed.
5. The I-HUD has a photo sensor that automatically adjusts the
brightness of the LEDs based on the intensity of the ambient light.
6. The I-HUD indicates a low battery condition by a single flashing
yellow LED. When the I-HUD Transmitter reaches a low battery
condition, a double flash of the yellow LED is displayed in the I-HUD.
If both the I-HUD and I-HUD Transmitter reach a low battery
condition, the I-HUD displays an alternating single and double flash
of the yellow LED. If this condition exists, return to fresh air, and
replace the batteries immediately.
7. The FireHawk M7 I-HUD is equipped with a self-test feature. Push
the green button for at least 3 seconds and release to initiate a self-
test routine. If the battery is low, the low battery LED will flash for 5
seconds after the self-test routine. The test feature is disabled if the I-
HUD is paired to an air mask.
INSTALLING AND REMOVING THE I-HUD
Installing the I-HUD
DO NOT use an I-HUD with a silicone Ultra Elite Facepiece
nosecup. The silicone nosecup will not provide adequate I-
HUD retention friction on the nosecup assembly. The
friction generated by the I-HUD retention arms will also
damage the body of the silicone nosecup. A Soft-Feel Hycar
nosecup must be used in conjunction with an I-HUD in an
Ultra Elite Facepiece. Ultra Elite XT Facepieces only contain
a Hycar nosecup.
1. Remove the nosecup and
unthread the speaking
diaphragm retaining ring
from facepiece.
© MSA 2017
Print Spec. 10000005196 (A)
CAUTION
Mat. 10122587
Doc. 10122587

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Firehawk I-HUD M7

  • Página 1 *Model number is located on the back of the I-HUD Transmitter. replace the batteries immediately. 7. The FireHawk M7 I-HUD is equipped with a self-test feature. Push NOTE: This quick reference guide provides user instructions for the green button for at least 3 seconds and release to initiate a self- the FireHawk M7 I-HUD receivers.
  • Página 2: Replacing The Battery

    Use only Duracell Ultra M3, Panasonic PhotoPower Cr2, or Energizer CR2 Photo lithium batteries in the FireHawk M7 I-HUD. 4. Re-install the nosecup. Use of other batteries will affect the performance of the unit and NOTE: The I-HUD retaining clip will not interfere with the void the Intrinsic Safety Approval.
  • Página 3 FIREHAWK M7 I-HUD QUICK REFERENCE GUIDE FireHawk M7 I-HUD LED Patterns Information/Alert Full to 3/4 3/4 to 1/2 1/2 to 1/3 FireHawk M7XT (Flashing) 1/2 to 1/4 FireHawk M7 (Flashing) 1/3 to 0 FireHawk M7XT (Flashing) 1/4 to 0 FireHawk M7 (Flashing)
  • Página 4 Si la pile est faible, la DEL de pile Instructions d’utilisation faible clignote pendant 5 secondes après la routine d’autotest. La fonction d’autotest est désactivée lorsque l’I-HUD est utilisé avec un Masque à air du FireHawk M7XT 10128861 masque à air. INSTALLATION ET RETRAIT DE L’I-HUD Masque à...
  • Página 5: Remplacement De La Pile

    5. Orienter l’I-HUD dans la pièce faciale de manière à ce que les Panasonic PhotoPower Cr2 ou Energizer CR2 Photo dans l’I-HUD tiges de rétention appuient légèrement contre les deux FireHawk M7. déflecteurs du demi-masque. L’utilisation d’autres types de piles compromettra le 6.
  • Página 6 Motifs des DEL du M7 I-HUD Information/Alerte Pleine jusqu’aux 3/4 De 3/4 à 1/2 De 1/2 à 1/3 FireHawk M7XT (clignotant) De 1/2 à 1/4 FireHawk M7 (clignotant) De 1/3 à 0 FireHawk M7XT (clignotant) De 1/4 à 0 FireHawk M7 (clignotant) Faible pile (clignotant) Pré-alarme PASS...
  • Página 7: Funcionamiento Del I-Hud Del Firehawk M7

    Respirador FireHawk M7 10082858 7. El I-HUD del FireHawk M7 cuenta con una función de prueba automática. Presione el botón verde durante por lo menos 3 segundos y suéltelo para dar inicio a la rutina de prueba automática. FUNCIONAMIENTO DEL I-HUD DEL FIREHAWK M7 Si la batería está...
  • Página 8: Reemplazo De La Batería

    GUÍA DE REFERENCIA RÁPIDA PARA EL I-HUD DEL FIREHAWK M7 7. Instale el I-HUD presionando el puente central hacia adelante. El mecanismo de bloqueo (brazo superior del clip de 1. Quite la copa nasal y sujeción) se envuelve en desenrosque el anillo de torno al puente del I-HUD retención del diafragma...
  • Página 9 GUÍA DE REFERENCIA RÁPIDA PARA EL I-HUD DEL FIREHAWK M7 Antes de colocar la tapa de la batería, asegúrese de que la junta tórica Verifique que el sistema de visualización I-HUD se encienda y realice su esté bien puesta, no esté dañada y no presente suciedad ni partículas secuencia de encendido antes de apagarse.

Este manual también es adecuado para:

I-hud m7xt

Tabla de contenido