Overview of possible operating and error messages
If an error occurs, the motor switches off permanently and a message is displayed.
Exception: "Under voltage" if there is a failure or the power supply switches off. In this
case the motor restarts when the power supply is switched on again.
If an error occurs, the system must be disconnected from the power supply. See
chapter 2.2 of the original operating manual "Non self-priming and self-priming pumps
with/without plastic lanterns (AK version)".
Error No.
Err 1
Err 2
Err 3
Err 4
Err 5
Err 7
Err 10
Err 20
Err 64
Err 97
Err 98
Related Documentation
The additional information compiled in this data sheet must be kept together with the
original Operating Manual for „Non self-priming and self-priming pumps with/without
plastic lanterns" and must be accessible to the relevant personnel at all times.
30 EN
VG 766.2130.052
Description
Undervoltage intermediate circuit
Overvoltage intermediate circuit
Supply voltage too low/too high
Temperature at the power electronics too high
Overtemperature motor
Overcurrent electronics
Current measurement faulty
Abortion during start-up, overload
Short-circuit electronics
Simultaneous occurrence of several errors or
faults
Connection to the control unit faulty
10/2014