Preventative Maintenance - Monster MST13003 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREVENTATIVE MAINTENANCE

This is the safety alert symbol used for the PREVENTATIVE MAINTENANCE section of this manual to alert you to potential
personal injury hazards. Obey all instructions to avoid possible injury or death.
IMPORTANT: Any jack found to be defective as a result of worn parts due to lack of lubrication, or hydraulic system
contaminated with water, rust and/or foreign materials is not eligible for warranty consideration.
1. Always store the jack in a well protected area where it will not be exposed to inclement weather, corrosive vapors, abrasive dust, or
any other harmful elements. The jack must be cleaned of water, snow, sand, grit, oil, grease or other foreign matter before using.
2. The jack must be lubricated periodically in order to prevent premature wearing of parts. A general purpose grease must be applied to
the threads on the extension screw. Do not lubricate any portion of the lift saddle and make sure the saddle is free from grease, any
kind of lubricant, or debris before using the jack.
3. It should not be necessary to refill or top off the reservoir with hydraulic fluid unless there is an external leak. An external leak requires
immediate repair which must be performed in a dirt-free environment by qualified hydraulic repair personnel who are familiar with this
equipment. Authorized Service Centers are recommended. IMPORTANT: In order to prevent seal damage and jack failure, never use
alcohol, hydraulic brake fluid, or transmission oil in the jack. Use hydraulic jack oil.
4. Every jack owner is responsible for keeping the jack label clean and readable. Use a mild soap solution to wash external surfaces of
the jack but not any moving hydraulic components.
5. Do not attempt to make any hydraulic repairs unless you are a qualified hydraulic repair person that is familiar with this equipment.
TROUBLESHOOTING
PROBLEM: UNIT WILL NOT LIFT RATED LOAD.
ACTION: Purge air from hydraulic system by following procedure under SETUP.
PROBLEM: UNIT WILL NOT SUSTAIN RATED LOAD OR FEELS "SPONGY" UNDER RATED LOAD.
ACTION: Purge air from hydraulic system as above.
PROBLEM: UNITE WILL NOT LIFT TO FULL HEIGHT.
ACTION: Purge air from hydraulic system as above or check oil level in reservoir.
PROBLEM: UNIT STILL DOES NOT OPERATE.
ACTION: Contact your place of purchase for details on handling warranty.